This is a
With the Aeotec Radiator Thermostat you get many functions. It regulates the room temperature to your comfort. For the best use it is equipped with FLiRS (Frequently Listening Receiver Slave) and reacts immediately to incoming commands of the Z-Wave controller. Furthermore the device is able to be connected to an external Z-Wave temperature sensor. Because of that the thermostat refers to the temperature of the external sensor, which can be placed in the middle of the room. The display of the thermostat has a background light and has a big LCD screen. Besides you can also lock the local buttons as a child protection.The multicolor LED of the central button allows a intuitive usability because the User is invited to follow the instruction based on the blinking LED of the middle butto. The TRV can either be used as heating thermostat or as a actuator depending on the configuration of the device. The measured temperature or the position of the actuator of the thermostat are transfered to the Z-Wave gateway.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline group to Gateway |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal orientation |
1 | LCD content inverted |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LCD always on |
5 - 30 | LCD timeout in seconds |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Backlight disabled |
1 | Backlight enabled |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Battery reporting disabled |
1 | Battery reporting enabled |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 50 | Reporting Delta in 1/10 Celcius |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 100 | Reporting Delta in percent |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Detection disabled |
1 - 3 | Sensitivity level |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-50 - 50 | Offset in 1/10 Celcius |
-128 | Temperature is supplied externaly |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 49 FW: 0.16:00.10 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-19086734 |
Z-Wave Product Id | 0x0371.0x0002.0x0015 |
Thermostat HVAC Systems Supported | Heat Only |
Thermostat Modes | Energy Save Heat |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |