Quickstart

This is a secure Alarm Sensor for CEPT (Europe). To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The PAT05 multi-sensor is a device that allows you to check the air quality in your home. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just set the sensor on the wall of the rooms you would like to control, and you are ready to go. Moreover, the PAT05 can be integrated to other Z-Wave certified devices, and controlled with Philio app Home Mate 2. You can now protect your family and make sure there are no gas leaks that can harm those you love the most. Set up your PAT05 to send regular notifications and take control even when not at home.This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-WaveTM enabled networks.The product supports Over The Air(OTA) feature for the products firmware upgrade.This product can be included and operated in any Z-WaveTM networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.The device adopt the Z-WaveTM 500 series chip, when your Z-WaveTM network system is all made by Z-WaveTM 500 series devices. The network system will have the advantages as below.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Group 1 command list COMMAND_CLASS_DEVICE_RESET_LOCALLY

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 10: TVOC Threshold line 3

TVOC difference return:The Unit is 100ppb.0 means turn off TVOC detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 11: TVOC Threshold line 4

TVOC difference return:The Unit is 100ppb.0 means turn off TVOC detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 12: TVOC Threshold line 5

TVOC difference return:The Unit is 100ppb.0 means turn off TVOC detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 13: Customer Function

Customer function switch, using bit control.Caution: The value is unsigned byte, the range is from 0x00 ~ 0x7F.
Size: 1 Byte, Default Value: 1

Setting Description

Parameter 14: ECO2 Auto Report Time

The interval time for auto report the eCO2.The default value is 1. The tick time can setting by the configuration No.16.
Size: 1 Byte, Default Value: 1

Setting Description

Parameter 15: TVOC Auto Report Time

The interval time for auto report the TVOC.The default value is 1. The tick time can setting by the configuration No.16.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 16: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.14 and No.15.The unit is 1 minute.Caution1: The value is unsigned byte, the range is from 0x00 ~ 0x7F.
Size: 1 Byte, Default Value: 60

Setting Description

Parameter 17: eCO2 Differential percent Report

The eCO2 Differential to report.0 means turn off this function.The unit is percentage.Enable this function the device will detect every percentage.And when the lightSensor is over 10 percentage, it will continue report.
Size: 1 Byte, Default Value: 10

Setting Description

Parameter 18: TVOC Differential percent Report

The TVOCDifferential to report.0 means turn off this function.The unit is percentage.Enable this function the device will detect every percentage.And when the lightSensor is over 10 percentage, it will continue report.
Size: 1 Byte, Default Value: 10

Setting Description

Parameter 3: eCO2 Threshold line 1

eCO2 difference return:The Unit is 100ppm.0 means turn off eCO2 detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 4: eCO2 Threshold line 2

eCO2 difference return: The Unit is 100ppm. 0 means turn off eCO2 detected function. When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 5: eCO2 Threshold line 3

eCO2 difference return: The Unit is 100ppm. 0 means turn off eCO2 detected function. When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 6: eCO2 Threshold line 4

eCO2 difference return: The Unit is 100ppm. 0 means turn off eCO2 detected function. When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 7: eCO2 Threshold line 5

eCO2 difference return: The Unit is 100ppm. 0 means turn off eCO2 detected function. When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 8: TVOC Threshold line 1

TVOC difference return:The Unit is 100ppb.0 means turn off TVOC detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 9: TVOC Threshold line 2

TVOC difference return:The Unit is 100ppb.0 means turn off TVOC detected function.When there is a set value, it means that it will exceed or fall below the report.
Size: 1 Byte, Default Value: 0

Setting Description

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01:01.01
Z-Wave Version 6.81.03
Certification ID ZC10-19096741
Z-Wave Product Id 0x013C.0x0002.0x0052
Firmware Updatable Not Updatable
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Notification V8
  • Powerlevel
  • Security
  • Security 2
  • Sensor Multilevel V11
  • Supervision
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.