Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The PAT12 sensor is easy to use and very convenient for your home. Just set the sensor on the wall in the rooms you would like to control, and you are ready to go. Moreover, the PAT12 can be integrated to other Z-Wave certified devices, and controlled with Philio app Home Mate 2. You can now protect your family and your business and make sure that air you are breathing is safe. Set up your PAT12 to send regular notifications and take control even when not at home.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Used for returned events.

Configuration Parameters

Parameter 1: Auto report CO2 Concentra- tion time

Units of 1 minute.
Size: 2 Byte, Default Value: 60

Setting Description
1 - 32767 Units of 1 minute.

Parameter 2: CO2 Concentration differen- tial report

Units of 1 %.0 means turn off the report
Size: 1 Byte, Default Value: 10

Setting Description
1 - 100 Units of 1 %

Parameter 3: Baseline level 1

Units of 100 ppm.0 means turn off the report
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Units of 100 ppm.

Parameter 4: Baseline level 2

Units of 100 ppm.0 means turn off the report
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Units of 100 ppm.

Parameter 5: Baseline level 3

Units of 100 ppm.0 means turn off the report
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Units of 100 ppm.

Parameter 6: Baseline level 4

Units of 100 ppm.0 means turn off the report
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Units of 100 ppm.

Parameter 7: Baseline level 5

Units of 100 ppm.0 means turn off the report
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Units of 100 ppm.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.02:01.02
Z-Wave Version 6.81.03
Certification ID ZC10-19096749
Z-Wave Product Id 0x013C.0x0002.0x006B
Firmware Updatable Not Updatable
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor