The multi sensor is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network.This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-WavePlus products. Z-WaveTM enabled devices displayingthe Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-WaveTM enabled networks. The product supports Over TheAir(OTA) feature for the products firmware upgrade. This product can be included and operated in any Z-Wave TM network with other Z-Wave TMcertified devices from other manufacturers and/or other applications.All non-battery operated nodes within the networkwill act as repeaters regardless of vendor to increase reliability of the network. The device adopt the Z-Wave TM 500 series chip, when your Z-Wave TM network system is all made by Z-Wave TM 500 series devices. The network system will have the advantages as below.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Group 1 command list COMMAND_CLASS_DEVICE_RESET_LOCALLY |
2 | 5 | Group 2 command list COMMAND_CLASS_BASIC |
Setting the BASIC command value to turn on the light. The 0x63means turn on the light. For dimmer equipment 1 to 99means the light strength.0 means turn off the light. Size: 1 Byte, Default Value: 99
Setting | Description |
---|
The interval time for auto report the temperature. The default value is 12. The tick time can setting by the configuration No.11. Size: 1 Byte, Default Value: 12
Setting | Description |
---|
The interval time for auto report each tick. Setting this configuration will effect configuration No.8, No.9 and No.10.The unit is 1 minute. Size: 1 Byte, Default Value: 30
Setting | Description |
---|
The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report.Enable this functionality will cause some issue please see the detail in the Temperature Report section. Size: 1 Byte, Default Value: 10
Setting | Description |
---|
The LightSensor Differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every percentage. And when the lightSensor is over 20 percentage, it will continue report. Size: 1 Byte, Default Value: 20
Setting | Description |
---|
PIR Trigger Mode:Mode1: NormalMode2: DayTime Mode3: AtNight Size: 1 Byte, Default Value: 1
Setting | Description |
---|
PIR night line Lux conditions:LightSensor determines whether the level is night. (Unit 1Lux) Size: 2 Byte, Default Value: 2
Setting | Description |
---|
PIR sensitivity settings.0 means disable the PIR motion.1 means the lowest sensitivity,99 means the highest sensitivity.High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. Size: 1 Byte, Default Value: 80
Setting | Description |
---|
Operation mode. Using bit to control. Size: 1 Byte, Default Value: 1
Setting | Description |
---|
Customer function switch, using bit control. Size: 1 Byte, Default Value: 3
Setting | Description |
---|
In the normal mode, after the PIR motion detected, setting the re-detect time. 10 seconds per tick, default tick is 6 (60 seconds).Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.Notice: If this value bigger than the configuration setting NO. 7 There is a period after the light turned off and the PIR not start detecting. Size: 1 Byte, Default Value: 6
Setting | Description |
---|
After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 10 seconds per tick, default tick is 7 (70 seconds).0 means never send turn off light command. Size: 1 Byte, Default Value: 7
Setting | Description |
---|
The interval time for auto report the battery level. 0 means turn off auto report battery.The default value is 12. The tick time can setting by the configuration No.11. Size: 1 Byte, Default Value: 12
Setting | Description |
---|
The interval time for auto report the illumination. The default value is 12. The tick time can setting by the configuration No.11. Size: 1 Byte, Default Value: 0
Setting | Description |
---|
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.02:01.02 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19106767 |
Z-Wave Product Id | 0x013C.0x0002.0x0070 |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |