Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Ring Retrofit Alarm Kit is a Wired-to-wireless bridge that connects to your existing hardwired contact sensors and transmits open/close events wirelessly to Ring Alarm. Connect up to 8 wired contact sensor zones to the device. Set up and configure the device using the Ring app. After installation and setup, monitor and receive notifications when doors and windows with wired sensors connected to Retrofit Alarm Kit open and close. The Ring Alarm Base Station is required to enable Retrofit Alarm Kit features and functions. Once setup, wired sensors connected to Retrofit Alarm Kit can be monitored just like other Ring Alarm sensors in the system.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Group one is a lifeline group who will receive unsolicited messages relating to case tamper notifications, battery level notifications, Wake-Up notifications, and Device Reset Notifications.
2 1 Group two is intended to be used with multi-channel association for a controller to subscribe to contact switch open/close notifications sent encapsulated from each of the eight endpoints one for each contact switch. Each endpoint must be enabled by putting the controllers node ID into the devices Association Group 2 with either an Association Set encapsulated with Multi-Channel Encapsulation OR a Multi-Channel Association Set encapsulated with Multi-Channel Encapsulation.

Configuration Parameters

Parameter 1: Heartbeats

Number of seconds between periodic battery reports. (Heartbeats)
Size: 2 Byte, Default Value: 4200

Setting Description
255 - 4200 Number of seconds between periodic battery reports. (Heartbeats)

Parameter 2: One-Time Wakeup Notification

One-Time Wakeup Notification. (In addition to normal Wakeup Notification)
Size: 2 Byte, Default Value: 0

Setting Description
1 - 3600 One-Time Wakeup Notification. (In addition to normal Wakeup Notification)

Parameter 3: Application Level Retries

Number of Application Level Retries after a failed transmission defined as either not ACKed or Supervision Report not returned when encapsulated.
Size: 1 Byte, Default Value: 5

Setting Description
1 - 15 Number of Application Level Retries after a failed transmission defined as either not ACKed or Supervision Report not returned when encapsulated.

Parameter 4: seconds to sleep

The minimum number of seconds to sleep between application level retries.
Size: 1 Byte, Default Value: 6

Setting Description
1 - 60 The minimum number of seconds to sleep between application level retries.

Parameter 5: Application Retry Multiplier

Application Retry Multiplier. The number of seconds between a current application retry is the count of retries multiplied by this number in seconds + a small random delay.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 5 Application Retry Multiplier. The number of seconds between a current application retry is the count of retries multiplied by this number in seconds + a small random delay.

Parameter 6: wait for a Supervisory Report

The number of milliseconds to wait for a Supervisory Report in response to a Supervisory encapsulated Get.
Size: 2 Byte, Default Value: 1500

Setting Description
500 - 5000 The number of milliseconds to wait for a Supervisory Report in response to a Supervisory encapsulated Get.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00:01.00
Z-Wave Version 6.81.03
Certification ID ZC10-19116787
Z-Wave Product Id 0x0346.0x0B01.0x0101
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor