This is a secure Multilevel Switch - Color Tunable Multilevel for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FEATURES:- Manual or Z-Wave on/off, brightness, and RGBW color control- Perfect for programming your existing RGBW LED strip- Energy monitoring in live mode and over time- Double tap to full brightness feature + optional scene control- Remembers and restores on/off status after power failure- Built-in Z-Wave Plus signal repeater to extend network range- S2 security protocol and AES-128 bank-grade encryptionSPECIFICATIONS:- Model Number: ZEN31- Z-Wave Signal Frequency: 908.42 MHz- Power: 12 / 24 V DC (Do NOT connect to 120 V AC high-voltage power!)- Maximum Load: 10 A total between all channels (6 A per channel max); 120 W total when powered by 12 V DC / 240 W total when powered by 24 V DC- Range: Up to 100 feet line of sight - Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only- Dimensions: 1.67 x 1.5 x 0.69

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 reports the device status and allowsfor assigning single device only (main controller by default).
2 5 allows to synchronize state of other Zooz RGBW Dimmers ZEN31 - do not use with other devices.
3 5 is used to turn the associateddevices on/off reflecting IN1 operation.
4 5 is used to change brightness level ofassociated devices reflecting IN1 operation.
5 5 is used to turn the associateddevices on/off reflecting IN2 operation.
6 5 is used to change brightness level of associated devices reflecting IN2 operation.
7 5 is used to turn the associated devices on/off reflecting IN3 operation.
8 5 is used to change brightness level of associated devices reflecting IN3 operation.
9 5 is used to turn the associated devices on/off reflecting IN4 operation.
10 5 is used to change brightness level of associated devices reflecting IN4 operation.

Configuration Parameters

Parameter 1: On Off Status After Power Failure

Set the on off status for the RGBW Dimmer after power failure.
Size: 1 Byte, Default Value: 0

Setting Description
0 forced to OFF (regardless of state prior to power outage)
1 remem-bers and restores on/off status after power failure
2 forced to ON (regard-less of state prior to power outage)

Parameter 150: RGBW / HSB Wall Switch Mode

Choose how switches connected to the input terminals control your LED strip. In the default RGBW mode, each switch connected to each input terminal controls the RGBW channels separately (so IN1 for red, IN2 for green, etc) with a single click for ON/OFF, double click to full brightness, and press-and-hold to dim (momentary switches only). In the HSB mode, IN1 controls hue, IN2saturation, IN3brightness, IN4white with single click for last set value or value 0, double click to max value, and press-and-hold to set custom value.
Size: 1 Byte, Default Value: 0

Setting Description
0 RGBW mode (default)
1 HSB mode

Parameter 151: Physical Ramp Rate

Adjust the ramp rate for your RGBW dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated from the connected wall switch.
Size: 2 Byte, Default Value: 3

Setting Description
0 instant on/off
1 - 127 seconds
128 - 254 1 - 127 minutes

Parameter 152: Z-Wave Ramp Rate

Adjust the ramp rate for your RGBW dimmer when operated remotely from the Z-Wave hub.
Size: 2 Byte, Default Value: 3

Setting Description
0 instant on/off
1 - 127 seconds
128 - 254 1 - 127 minutes

Parameter 154: Single Click ON Trigger for Associated Devices

Set the status or brightness level triggering other associated devices in your network if the dimmer is turned ON with a single click. Each of the 4 available bytes refers to one channel, starting with IN1 and ending with IN4. This setting applies to basic set and switch multilevel commands sent to associated devices in the appropriate association group.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 99 custom brightness level
255 ON

Parameter 155: Single Click OFF Trigger for Associated Devices

Set the status or brightness level triggering other associated devices in your network if the dimmer is turned OFF with a single click. Each of the 4 available bytes refers to one channel, starting with IN1 and ending with IN4. This setting applies to basic set and switch multilevel commands sent to associated devices in the appropriate association group.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 99 custom brightness level
255 ON

Parameter 156: Double Click ON Trigger for Associated Devices

Set the status or brightness level triggering other associated devices in your network if the dimmer is turned ON with a double click. Each of the 4 available bytes refers to one channel, starting with IN1 and ending with IN4. This setting applies to basic set and switch multilevel commands sent to associated devices in the appropriate association group.
Size: 4 Byte, Default Value: 99

Setting Description
0 - 99 custom brightness level
255 ON

Parameter 157: Preset Programs

Enable one of the preset animated color programs to set the mood with a click.
Size: 1 Byte, Default Value: 0

Setting Description
0 preset programs disabled (default)
6 fireplace
7 storm
8 rainbow
9 polar lights
10 police (strobing red, white, and blue)

Parameter 20: Switch / Input Type for IN1

Choose the input / switch type you want to connect to the IN1 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 analog sensor with no pull-up
1 analog sensor with pull-up
2 momentary switch (default)
3 toggle switch (state changes whenever the switch is toggled)
4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter 21: Switch / Input Type for IN2

Choose the input / switch type you want to connect to the IN2 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 analog sensor with no pull-up
1 analog sensor with pull-up
2 momentary switch (default)
3 toggle switch (state changes whenever the switch is toggled)
4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter 22: Switch / Input Type for IN3

Choose the input / switch type you want to connect to the IN3 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 analog sensor with no pull-up
1 analog sensor with pull-up
2 momentary switch (default)
3 toggle switch (state changes whenever the switch is toggled)
4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter 23: Switch / Input Type for IN4

Choose the input / switch type you want to connect to the IN4 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 analog sensor with no pull-up
1 analog sensor with pull-up
2 momentary switch (default)
3 toggle switch (state changes whenever the switch is toggled)
4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter 40: Scene Control for IN1

Assign scene activation trigger for IN1 terminal. Enter the sum of values to enable more than 1 trigger.
Size: 1 Byte, Default Value: 15

Setting Description
0 scene control disabled
1 click / toggle the connected switch once to trigger a scene
2 click / toggle the connected switch twice to trigger a scene
4 click / toggle the connected switch 3 times to trigger a scene
8 hold and release the connected momentary switch to trigger a scene

Parameter 41: Scene Control for IN2

Assign scene activation trigger for IN2 terminal. Enter the sum of values to enable more than 1 trigger.
Size: 1 Byte, Default Value: 15

Setting Description
0 scene control disabled
1 click / toggle the connected switch once to trigger a scene
2 click / toggle the connected switch twice to trigger a scene
4 click / toggle the connected switch 3 times to trigger a scene
8 hold and release the connected momentary switch to trigger a scene

Parameter 42: Scene Control for IN3

Assign scene activation trigger for IN3 terminal. Enter the sum of values to enable more than 1 trigger.
Size: 1 Byte, Default Value: 15

Setting Description
0 scene control disabled
1 click / toggle the connected switch once to trigger a scene
2 click / toggle the connected switch twice to trigger a scene
4 click / toggle the connected switch 3 times to trigger a scene
8 hold and release the connected momentary switch to trigger a scene

Parameter 43: Scene Control for IN4

Assign scene activation trigger for IN4 terminal. Enter the sum of values to enable more than 1 trigger.
Size: 1 Byte, Default Value: 15

Setting Description
0 scene control disabled
1 click / toggle the connected switch once to trigger a scene
2 click / toggle the connected switch twice to trigger a scene
4 click / toggle the connected switch 3 times to trigger a scene
8 hold and release the connected momentary switch to trigger a scene

Parameter 62: Power Report Frequency

Choose howoften you want your RGBW Dimmer to report power consumption (W) to yourcontroller. The number entered as value corresponds to the number of seconds. So if 3600 is entered by default, the RGBW Dimmer will report power consumption every hour. Power reports are sent in at least 30-second intervals.
Size: 2 Byte, Default Value: 3600

Setting Description
0 disabled (it will not report power consumption based on the fre- quency setting)
30 - 32400 seconds

Parameter 63: Analog Sensor Voltage Reporting / Trigger Threshold

Choose how you want your RGBW Dimmer to report voltage changes from the connected analog sensors and trigger status change on the output. The number entered as value corresponds to decimal values in voltage change. So if 5 is entered by default, the RGBW Dimmer will report any change in voltage of the connected sensor over 0.5 V. This setting is only in effect if at least one of Parameters 2023 is set to value 0 or 1 (input is set to analog sensor mode).
Size: 2 Byte, Default Value: 5

Setting Description
0 disabled (it will not report voltage based on value change)
1 - 100 0.110 V

Parameter 64: Analog Sensor Report Frequency

Choose howoften you want your RGBW Dimmer to report voltage changes from the connected analog sensors to your hub. The number entered as value corresponds to the number of seconds. So if 3600 is entered as value, the RGBW Dimmer will report voltage from connected analog sensors every hour (independent of the threshold set in parameter 63). Voltage reports are sent in at least 30-second intervals. This setting is only in effect if at least one of Parameters 2023 is set to value 0 or 1 (input is set to analog sensor mode).
Size: 2 Byte, Default Value: 0

Setting Description
0 disabled (it will not report voltage based on the frequency setting)
30 - 32400 seconds

Parameter 65: Energy Report Threshold

Choose how you want your RGBW Dimmer to report energy use (kWh) to your hub. The number entered as value corresponds to decimal values in energy usage change. So if 10 is entered by default, the RGBW Dimmer will report any change in energy use over 0.1 kWh. Energy reports are sent in at least 30-second intervals.
Size: 2 Byte, Default Value: 10

Setting Description
0 disabled (it will not report energy use based on value change)
1 - 500 0.01 - 5 kWh

Parameter 66: Energy Report Frequency

Choose howoften you want your RGBW Dimmer to report energy (kWh) to your controller. The number entered as value corresponds to the number of seconds. So if 3600 is entered by default, the RGBW Dimmer will report energy use every hour (independent of the threshold set in parameter 65). Energy reports are sent in at least 30-second intervals.
Size: 2 Byte, Default Value: 3600

Setting Description
0 disabled (it will not report energy use based on the frequency setting)
30 - 32400 seconds

Technical Data

Hardware Platform ZM5101
Device Type Multilevel Switch - Color Tunable Multilevel
Network Operation Always On Slave
Firmware Version HW: 2 FW: 5.00:05.00:01.00
Z-Wave Version 6.81.03
Certification ID ZC10-19126818
Z-Wave Product Id 0x027A.0x0902.0x2000
Z-Wave Scene Type Central Scene
Color Black
Frequency XXfrequency
Maximum transmission power XXantenna
Multilevel Switch - Color Tunable Multilevel