This is a
The remote control is a Z-Wave device that can both controlother Z-Wave devices and activate scenes in Gateways.Although it is controlling other devices, the device cannot actas Z-Wave network controller (primary or secondary) and willalways need a Z-Wave network controller to be added into aZ-Wave network.This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.The remote control has following functions:1. Control of groups of other Z-Wave devices using ON, OFF andDim commands.2. Activation of scenes in Gateway mode.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. Send Command Class u0022Device Reset Locally Notification V1u0022 toassociated devices of this group to report factory reset information when factory reset the remote control.2. When remote control battery power value changes, sendCommand Class u0022Battery Report V1u0022 to associated devices of thisgroup to report power value information.3. Short press or press and hold down any button to send sceneactivation command to the associated devices of this group using Command Class Central Scene Notification V3 |
2 | 5 | 1. Short press I1 / O1 button of Group 2 to send ON/OFFcommand to associated devices of this group using CommandClass u0022Basic Set V2u0022.2. Press and hold down I1 / O1 button of Group 2 to send light intensity increase/decrease command to associated devices of this group using Command Class u0022Multilevel V4u0022.3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20.4. Press and hold down Scene button S1/S2, direct control ofassociated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. |
3 | 5 | 1. Short press I2 / O2 button of Group 3 to send ON/OFFcommand to associated devices of this group using CommandClass u0022Basic Set V2u0022.2. Press and hold down I2 / O2 button of Group 3 to send light intensity increase/decrease command to associated devices of this group using Command Class u0022Multilevel V4u0022.3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20.4. Press and hold down Scene button S1/S2, direct control ofassociated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. |
4 | 5 | 1. Short press I3 / O3 button of Group 4 to send ON/OFFcommand to associated devices of this group using CommandClass u0022Basic Set V2u0022.2. Press and hold down I3 / O3 button of Group 4 to send lightintensity increase/decrease command to associated devices of this group using Command Class u0022Multilevel V4u0022.3. Short press Scene button S1/S2, direct control of associateddevices using Scene Activation Set, Scene ID = 0x10 / 0x20.4. Press and hold down Scene button S1/S2, direct control ofassociated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. |
5 | 5 | 1. Short press I4 / O4 button of Group 5 to send ON/OFFcommand to associated devices of this group using CommandClass u0022Basic Set V2u0022.2. Press and hold down I4 / O4 button of Group 5 to send lightintensity increase/decrease command to associated devices of this group using Command Class u0022Multilevel V4u0022.3. Short press Scene button S1/S2, direct control of associateddevices using Scene Activation Set, Scene ID = 0x10 / 0x20.4. Press and hold down Scene button S1/S2, direct control ofassociated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. |
Value=0x55AA, other values are invalid,factory reset the Remote Control Size: 2 Byte, Default Value: 21930
Setting | Description |
---|---|
21930 | factory reset |
Hardware Platform | ZM5101 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 1.26 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-20066927 |
Z-Wave Product Id | 0x0330.0x0300.0xb302 |
Firmware Updatable | Updatable by Consumer by RF |
Z-Wave Scene Type | Central Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |