Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Vitrum can easily be installed in common flush-mounting boxes, and does not require buses, control units or additional wiring. It uses the most widespread technologies in the world, and offers an advanced and intuitive user experience and is offered in different collections to choose the style that best suits your needs. The great versatility of Vitrum simplifies home automation and makes it available to everyone.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 20 Lifeline reportAdd Controller Node ID to the list of Node ID destinations belonging to the Lifeline Group, in order to let the controller receive Central Scene Notification report andDevice Reset Locally Notification reports.Lifeline report with End Point informationAdd both Controller Node ID and Controller End Point to the list of End Points belonging to the Lifeline Group, in order to let the controller receive Central Scene Notification report with the End Point source address information. That may be achieved by sending the Multichannel Association Set Command Class and filling Multi Channel Node ID field with the Controller Node ID and End Point field with the Controller End Point.
2 20 Add Node IDs to the list of Node ID destinations belonging to the Button 1 Control group in order control the added nodes by sending Basic Set commands.
3 20 Add Node IDs to the list of Node ID destinations belonging to the Button 2 Control group in order to control the added nodes by sending Basic Set commands.
4 20 Add Node IDs to the list of Node ID destinations belonging to the Button 3 Control group in order to control the added nodes by sending Basic Set commands.
5 20 Add Node IDs to the list of Node ID destinations belonging to the Button 4 Control group in order to control the added nodes by sending Basic Set commands.
6 20 Add Node IDs to the list of Node ID destinations belonging to the Button 5 Control group in order to control the added nodes by sending Basic Set commands.
7 20 Add Node IDs to the list of Node ID destinations belonging to the Button 6 Control group in order to control the added nodes by sending Basic Set commands.

Configuration Parameters

Parameter 10: Button N.4 Off status LED

Color of LED associated to push-button N.4 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 11: Button N.5 Off status LED

Color of LED associated to push-button N.5 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 12: Button N.6 Off status LED

Color of LED associated to push-button N.6 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 13: Button N.1 On status LED

Color of LED associated to push-button N.1 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 14: Button N.2 On status LED

Color of LED associated to push-button N.2 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 15: Button N.3 On status LED

Color of LED associated to push-button N.3 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 16: Button N.4 On status LED

Color of LED associated to push-button N.4 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 17: Button N.5 On status LED

Color of LED associated to push-button N.5 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 18: Button N.6 On status LED

Color of LED associated to push-button N.6 reporting an on state.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 206: Buttons Max. Brightness

Maximum brightness of LEDs associated to push-buttons.Remark: value must be grateror equal than Parameter N.207.
Size: 1 Byte, Default Value: 100

Setting Description
5 - 100 LEDs maximum brightness

Parameter 207: Buttons Min. Brightness

Maximum brightness of LEDs associated to push-buttons.Remark: value must be lessor equal than Parameter N.206.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 100 LED minum brightness.

Parameter 209: Buzzer

Buzzer operating status.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: disabled 1: enabled

Parameter 218: Front-end Buttons lock

Buttons lock status
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: disabled; 1: enabled.

Parameter 25: Output port connected to Button N.1

Output port connected to Button N.1.Remark: connecting a button to an output port already connected to another different button, will force the previously connected button to be automatically disconnected
Size: 1 Byte, Default Value: 1

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 26: Output port connected to Button N.2

Output port connected to Button N.2.Remark: connecting a button to an outputport already connected to another differentbutton, will force the previously connectedbutton to be automatically disconnected
Size: 1 Byte, Default Value: 2

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 27: Output port connected to Button N.3

Output port connected to Button N.3.Remark: connecting a button to an outputport already connected to another differentbutton, will force the previously connectedbutton to be automatically disconnected
Size: 1 Byte, Default Value: 3

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 28: Output port connected to Button N.4

Output port connected to Button N.4.Remark: connecting a button to an outputport already connected to another differentbutton, will force the previously connectedbutton to be automatically disconnected
Size: 1 Byte, Default Value: 4

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 29: Output port connected to Button N.5

Output port connected to Button N.5.Remark: connecting a button to an outputport already connected to another differentbutton, will force the previously connectedbutton to be automatically disconnected
Size: 1 Byte, Default Value: 5

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 30: Output port connected to Button N.6

Output port connected to Button N.6.Remark: connecting a button to an outputport already connected to another differentbutton, will force the previously connectedbutton to be automatically disconnected
Size: 1 Byte, Default Value: 6

Setting Description
0 - 6 0: Disconnected; 1: Button connected to Output Port 1; 2: Button connected to Output Port 2; 3: Button connected to Output Port 3; 4: Button connected to Output Port 4; 5: Button connected to Output Port 5; 6: Button connected to Output Port 6.

Parameter 31: Basic Set On from Group 2

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 32: Basic Set On from Group 3

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 33: Basic Set On from Group 4

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 34: Basic Set On from Group 5

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 35: Basic Set On from Group 6

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 36: Basic Set On from Group 7

Value of the Basic Set command sent:0: 99 (0x63)1: 255 (0xFF)
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: 99 (0x63) 1: 255 (0xFF)

Parameter 7: Button N.1 Off status LED

Color of LED associated to push-button N.1 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 LED is off: 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 8: Button N.2 Off status LED

Color of LED associated to push-button N.2 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Parameter 9: Button N.3 Off status LED

Color of LED associated to push-button N.3 reporting an off state.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 7 0: LED is off; 1: Red; 2: Green; 3: Blue; 4: Yellow; 5: Magenta; 6: Cyan; 7; White.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 5.50:01.01
Z-Wave Version 6.71.03
Certification ID ZC10-20076946
Z-Wave Product Id 0x010A.0x8161.0x2062
Firmware Updatable Not Updatable
Loads Controlled 10
Neutral Wire Required ok
Switch Type Decorator Paddle Push
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch