Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

It is smart plug type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can dim lights at home from your mobile phone separately, and manual dim light by push button .

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Lifeline
2 5 When the output of the MP21ZP Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The MP21ZP will automaticallysend out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
3 5 basic set command

Configuration Parameters

Parameter 1: Parameter 1

Restores state after power failure
Size: 1 Byte, Default Value: 0

Setting Description
0 The state before a power outage
1 outlet on
2 outlet on

Parameter 10: Parameter 10

Endpoint1 Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-ON Timer Disabled
1 Auto Turn-ON Timer Enabled

Parameter 11: Parameter 11

Endpoint1 Count Down Configuration(Turn on the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn on the output by time

Parameter 16: Parameter 16

Manual Control
Size: 1 Byte, Default Value: 1

Setting Description
0 Manual Control Disabled
1 Manual Control Enabled

Parameter 17: Parameter 17

Status LED Configuration
Size: 1 Byte, Default Value: 1

Setting Description
0 LED indicator will display power consumption whenever the device is plugged in
1 LED indicator will display power consumption whenever the device is ON in and will turn off
2 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on
3 Always OFF

Parameter 2: Parameter 2

Power Wattage Report Value Threshold
Size: 4 Byte, Default Value: 10

Setting Description
0 - 65535 Power Wattage Report Value Threshold(Wattage)

Parameter 3: Parameter 3

Power Wattage Report Frequency (Timer)
Size: 4 Byte, Default Value: 30

Setting Description
30 - 2678400 Power Wattage Report Frequency (Timer)

Parameter 4: Parameter 4

Energy (kWh) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
300 - 2678400 Energy (kWh) Report Frequency (Timer)

Parameter 5: Parameter 5

Voltage (V) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
300 - 2678400 Voltage (V) Report Frequency (Timer)

Parameter 6: Parameter 6

Electricity (A) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
300 - 2678400 Electricity (A) Report Frequency (Timer)

Parameter 7: Parameter 7

Overload Protection (Current)
Size: 1 Byte, Default Value: 13

Setting Description
1 - 16 Overload Protection (Current)

Parameter 8: Parameter 8

Endpoint1 Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-OFF Timer Disabled
1 Auto Turn-OFF Timer Disabled

Parameter 9: Parameter 9

Endpoint1 Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn off the output by time

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-21077045
Z-Wave Product Id 0x0312.0xFF00.0xFF0E
Color White
Switch Type Decorator Paddle Push
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch