This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product features: OLED display and touch buttons also as remote control other thermostatsfor heating Internal sensor for room temperature , externalInternal sensor for floor temperature Max Load 3680W @ 230V (resistive load),16A Alarm: over current, room temperature over heat Electric power measurement Internal overheatingprotection
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifelinesame main report |
2 | 5 | Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other Thermostatwhen operationchanges |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Temperature control reference selection Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | room sensor |
2 | floor sensor |
3 | room+floor sensor |
ROOM SENSOR temperature compensation setting,unit is 0.5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | value is-5~5 |
FLOOR SENSOR temperature compensation setting,unit is 0.5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | value is -5~5 |
Set how long the drying mode lasts, unit is minute Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 100 | value is5~100 minutes |
Set the mode after the drying mode ends Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | OFF |
1 | Manual mode (comfort mode) |
2 | Auto mode (energy save mode) |
3 | Away mode |
When to report temperature relative change threshold value actively, unit is 0.1 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | disable to report |
2 - 10 | report when the threshold value is 0.2 - 1 |
Time interval value for periodic report of temperature, humidity, unit is S. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | disable to report |
30 - 28800 | report when time interval value is 30~28800 s |
When to report power change absolute threshold, unit is W Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | disable to report |
1 - 100 | report when absolute threshold is 1W~100W |
When to report current change absolute threshold, unit is 0.1A Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | disable to report |
1 - 10 | report when absolute threshold is 0.1A~1A |
Over current detection max. value, unit is A. When detected current is over thisvalue, the device will turn off the relay and send NOTIFICATION CC. Size: 1 Byte, Default Value: 16
Setting | Description |
---|---|
0 | disable over current detection |
5 - 16 | over current detection max value |
When to report voltage change absolute threshold, unit is 1 V Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | disable to report |
1 - 10 | report when absolute threshold is 1~10 V |
Time interval value for periodic active report of Meterunit is S Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
60 - 2678400 | value is60~2678400 s |
The OLED display brightness when operate the device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 2 | low levelmid levelhigh level |
is parameter defines which sensor temperature will be displayed on Home page Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | indoor air temperature |
1 | external temperature (floor temperature) |
The time zone that the time parameters command adopts is UTC the time zone need to be set. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-12 - 12 | value is-12~12 |
Window open detect function temperature threshold: the Celsius degrees that the temperature decreases within 3 minutes, unit is 0.1 Celsius degree. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disbaled |
15 - 40 | the set temperature threshold |
Vibration level triggered by pressing buttons Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable vibration and buzzer |
1 | Low Level |
2 | High Level |
Whether to recover to settings before power failure or power reset. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | use default settings |
1 | recover to settings before power failure or power reset |
High temperature detection max. value, unit is , when either temperature sensor is higher than this value, the device will turn off the relay and send NOTIFICATION CC. Size: 1 Byte, Default Value: 45
Setting | Description |
---|---|
0 | disable this function |
20 - 60 | air temperature over value |
Temperature control hysteresis value setting, setting range 0.5-2,unit is 0.1 Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 20 | hysteresis value0.5~2 |
Auto mode (Energy save mode) temperature schedule. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | use schedule set by user |
1 | use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET |
Select floor temperature sensor type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | NTC/10K B(25/50)=3950 |
2 | NTC/15K B(25/50)=3950 |
3 | NTC/50K B(25/50)=3950 |
4 | NTC/100K B(25/50)=3950 |
Hardware Platform | ZM5101 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.24 |
Z-Wave Version | 6.82.00 |
Certification ID | ZC10-21097049 |
Z-Wave Product Id | 0x0330.0x0200.0xD013 |
Thermostat Power Source | |
Thermostat HVAC Systems Supported | Heat Only |
Thermostat Modes | Auto Changeover |
Electric Load Type | |
Firmware Updatable | Not Updatable |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |