This is a
Flood-Control is a universal, Z-Wave Plus compatible flood and temperature sensor. The device can be powered using the battery, 12/24V DC power supply, or both. A flood alarm is sent to the Z-Wave network devices or additionally to any external system through opening an NC contact using the external power supply.The device has built in temperature sensor that allows to monitor ambient temperature. Flood-Control is designed to be placed on the floor or mounted on a wall (in this case Flood-Control probes should be extended using addition wire). The device has a built-in visual LED indicator and an acoustic alarm.In addition, the sensor is equipped with a tilt sensor reporting tilt or movement to the main controller e.g. when someone has taken the Sensor from its original location. Flood-Control is sink-proof, which means it drifts on the water surface and keeps on sending alarm signal in case of substantial inundation of water.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline reports the device status and allowsfor assigning single device only (main controller by default). |
2 | 5 | Flood Control devices in this group willbe switched on or off when flood status changes (done via BASIC SETcommand frames). |
3 | 5 | Flood Alarm is assigned to the devicestatus - devices in this group will receive notification about flood detectionor cancellation. Useful for devices that can trigger alarms. |
4 | 5 | Tamper Alarm is assigned to the TMPbutton and tilt sensor - devices in this group will receive a notificationwhen the sensor is moved or the cover is taken off (which normallyholds the button). Useful for devices that can trigger alarms. Functionalitycan be altered by parameter 74. |
Determines time period (in seconds) by which a Flood-Control will retain the flood state after the flooding itself has ceased. The sensor will keep on reporting flooding to the main controller. This parameter setting does not affect acoustic and visual alarms, which turn off immediately after flooding ceases. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3600 | Alarm cancellation delay |
Parameter stores RGB colour value (see Table A3 for details). Size: 4 Byte, Default Value: 16711680
Setting | Description |
---|---|
0 - 16777215 | High temperature alarm indicator colour |
Parameter determines visual indicators operation. Setting to 0 turns the temperature LED indication off, saving battery life. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 2 | Temperature indication using LED visual indicator |
Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-10000 - 10000 | Temperature measurement compensation |
The device is able to report tamper alarms resulting from sensors tilt/movement or TMP button state change (e.g. taking off the top cover). Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 3 | Alarm frame sent to 1st and 4th Association Group activation |
The device is capable of automatically turning off alarm signalization after a certain amount of time. Long lasting alarm may reduce battery life, when constantly signalized. The parameter determines time after which alarm will become quiet - still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time specified in the parameter 76. When alarm status ceases, alarm will be turned off immediately. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Alarms signalization duration |
Parameter determines a time period after which an alarm will be turned back on (in case it was turned off by parameter 75 setting). It will also resend commands to 2nd and 3rd association groups as if the alarm was detected again. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Alarm signalization reactivation period |
Allows to turn off the internal flood sensor. Tamper and built in temperature sensor will remain active. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Flood sensor functionality turned off |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
0 - 7 | Associations in Z-Wave network security mode |
The parameter allows for the deactivation of visual and acoustic alarms. The parameter allows for increasing battery life. Setting changes will not affect the sensors communication with the main controller - the device will still send commands to association groups, alarms, and reports. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | Acoustic and visual signals On / Off in case of flooding |
Determines the requested on level to be sent to devices from 2nd association group upon flood event. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | Requested dimming level / roller blind opening level when sending turn on / open command to 2nd associationgroup devices |
This setting decides whether device turn off commands and alarm cancellation notifications will be sent to devices in 2nd and 3rd association groups (respectively)Setting the parameters value to 0 disables sending these two commands to associated devices. This means that these devices WILL NOT be informed when the flooding has ceased. It is still possible to cancel alarms in 3rd association group by choosing second (green) menu position (see section 8.2 - Visual indications) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group |
Time interval (in seconds) between consecutive measurements of battery level and temperature (done by built-in temperature sensor).If the temperature differs from previously reported by a value determined in parameter 12, it will be reported to the Z-Wave controller. In battery mode more significant battery level changes will be reported. Short time intervals mean more frequent communication, which results in shortened battery life.After consecutive FAILED and SUCCESSFUL communication attempts, the Sensor will go to standby mode. Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
1 - 65535 | Temperature measurement interval |
Determines a minimum temperature change value (insensitivity level), resulting in a temperature report being sent to the main controller, according to the parameter 10 settings. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 1000 | Temperature measurement hysteresis |
The parameter stores a temperature value, below which visual indicator blinks with a colour determined by a parameter 61 settings. By default the visual indicator blinks blue. Size: 2 Byte, Default Value: 1500
Setting | Description |
---|---|
-10000 - 10000 | Low temperature alarm threshold |
The parameter stores a temperature value, above which visual indicator blinks with a colour determined by the parameter 62 settings. By default the visual indicator blinks red. Size: 2 Byte, Default Value: 3500
Setting | Description |
---|---|
-10000 - 10000 | High temperature alarm threshold |
Parameter stores RGB colour value (see Table A3 for details). Size: 4 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 16777215 | Low temperature alarm indicator colour |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 3.04:03.04 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22047081 |
Z-Wave Product Id | 0x010F.0x0B01.0x1003 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |