This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Expanding the Yale nexTouch product line for even more applications, the new nexTouch Sectional Mortise Keypad Lock provides robust security for a wide range of commercial and multi-family buildings. Just like the original cylindrical nexTouch lock, it is ANSI/BHMA Grade 1 certified and offered in capacitive touchscreen or pushbutton keypad versions. With just the addition of a Z-Wave Plus module, you can add this lock to compatible smart home and alarm systems. Other standard features include voice-guided programming, privacy mode with Door Position Switch, 9V battery backup, support of up to 100 unique user codes, and more.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 1 or High Volume Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Level |
0x00 = OFF, 0xFF = ON default is 0xFF or ON. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | One Touch Locking Off |
255 | One Touch Locking On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Privacy Button Off |
255 | Privacy Button On |
01 = Lock will execute Reset To Factory.No default value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset to Factory Off |
1 | Reset to Factory On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFEnables the Escape Return mode of operation for thelock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Escape Return Mode Off |
127 | Escape Return Mode On |
10 to 2540 second. This value is represented asseconds X 10. (ie a value of 4 would mean a doorpropped timer of 40 seconds) Set to 0x00 to disableDoor Propped Alarm. Default = 0x00 (OFF) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Seconds |
0x00 = OFF, 0xFF = ON Default is 0xFF or ON.Used to enable/disable door condition alarms for locksthat support a door position sensor. Any lock that doesnot support DPS will always report 0x00. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | DPS Alarm Off |
255 | DPS Alarm On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Relock Off |
255 | Auto Relock On |
0x00 = NO deadbolt , 0xFF = YES deadbolt Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Deadbolt No |
255 | Deadbolt Yes |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode ofoperation with reduced sound and led brightness. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Eco Mode Off |
255 | Eco Mode On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf enabled then extending the deadbolt will put the lockinto Privacy Mode. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Privacy Mode Off |
255 | Privacy Mode On |
Each bit controls one alarm. 1 = alarm enabled, 0 =alarm disabled.0xFF = All Alarms on, Default is 0xFF.Bit 0: DPS Alarm (AX) (Duplicate of parameter 19.Values should be tied together)Bit 1: Deadbolt AlarmBit 2: Lever Rotated (Rx)Bit 37: Not Used Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | No Sensor Alarm |
255 | All Sensors Alarm |
1 to 180 seconds default is 3 seconds Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
3 - 180 | Seconds |
3 to 10 default is 5 times Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 10 | Times |
Set the lock language. Default is 1= English Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | English Language |
2 | Spanish Language |
3 | French Language |
10 to 127 seconds default is 60 seconds Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 127 | Seconds |
This sets the operating mode for the lock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal Mode (Default) |
1 | Vacation Mode (Keypad Locked Out) |
2 | Privacy Mode (Keypad Locked, RF Unlock Functional) |
3 | passage mode, Lock is permanently unlocked. |
Hardware Platform | ZM5101 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.78:32.27 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22067089 |
Z-Wave Product Id | 0x0129.0x8100.0x0A25 |
IP (Ingress Protection) Rated | ok |
Outdoor Use | ok |
Supported Notification Types | |
Door Lock Type | Deadbolt |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |