This is a
The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home.The module is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Each relay can be turned on/off individually using Z-WaveTM commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load.This unit is to be installed and sealed inside an electrical switch box.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | - (Lifeline) When the unit is powered up for first time, a Notification Report will be sent to the node of Group 1.-When performing Factory Reset, a Device Reset Locally Notification will be sent to the node of Group 1.-When relay is activated through the switch, the unit will send a Binary Switch Report to the node of Group 1. |
2 | 5 | When switch 1 is pressed, a BASIC SET command containing a value will be sent to the node of Group 2 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF). |
3 | 5 | -When switch 2 is pressed, a BASIC SET command containing a value will be sent to the node of Group 3 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF). |
Switch 1 Type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: momentary 1: toggle |
Switch 2 Type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: momentary 1: toggle |
Relay 1 Auto Off Time Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | 0: not auto off |
Relay 2 Auto Off Time Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | 0: not auto off |
Set whether to remember the last status of Relay 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 1: remember 0: do not remember |
Set whether to remember the last status of Relay 2 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 1: remember 0: do not remember |
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01:00.01 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-22067097 |
Z-Wave Product Id | 0x0060.0x0004.0x000E |
Electric Load Type | FluorescentIncandescentLED |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |