Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home.The module is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Each relay can be turned on/off individually using Z-WaveTM commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load.This unit is to be installed and sealed inside an electrical switch box.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 - (Lifeline) When the unit is powered up for first time, a Notification Report will be sent to the node of Group 1.-When performing Factory Reset, a Device Reset Locally Notification will be sent to the node of Group 1.-When relay is activated through the switch, the unit will send a Binary Switch Report to the node of Group 1.
2 5 When switch 1 is pressed, a BASIC SET command containing a value will be sent to the node of Group 2 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF).
3 5 -When switch 2 is pressed, a BASIC SET command containing a value will be sent to the node of Group 3 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF).

Configuration Parameters

Parameter 1: Parameter 1

Switch 1 Type
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: momentary 1: toggle

Parameter 2: Parameter 2

Switch 2 Type
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: momentary 1: toggle

Parameter 3: Parameter 3

Relay 1 Auto Off Time
Size: 1 Byte, Default Value: 0

Setting Description
0 - 127 0: not auto off

Parameter 4: Parameter 4

Relay 2 Auto Off Time
Size: 1 Byte, Default Value: 0

Setting Description
0 - 127 0: not auto off

Parameter 5: Parameter 5

Set whether to remember the last status of Relay 1
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 1: remember 0: do not remember

Parameter 6: Parameter 6

Set whether to remember the last status of Relay 2
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 1: remember 0: do not remember

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01:00.01
Z-Wave Version 6.81.03
Certification ID ZC10-22067097
Z-Wave Product Id 0x0060.0x0004.0x000E
Electric Load Type FluorescentIncandescentLED
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch