Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique pin codes for friends and family and remove codes whenever you need to. This Yale Real Living lock features Z-Wave Plus technology and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave Plus automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use!

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1 = High Volume, 2 = Low Volume, 3 =Silent. Default is 2 or Low Volume
Size: 1 Byte, Default Value: 2

Setting Description
1 - 3 Sound level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

Setting Description
0 One Touch Locking Off
255 One Touch Locking On

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Privacy Button Off
255 Privacy Button On

Parameter 13: Lock Status LED

0x00 = OFF , 0xFF=ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Lock Status LED Off
255 Lock Status LED On

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reset to Factory Off
255 Reset to Factory ON

Parameter 16: Escape Return Mode

0x00 = OFF, 0xFF = ON default is 0x00 or OFFEnables the Escape Return mode of operation for thelock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Escape Return Off
255 Escape Return On

Parameter 2: Auto Relock on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Relock On
255 Auto Relock OFF

Parameter 21: Eco Mode on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode ofoperation with reduced sound and led brightness.
Size: 1 Byte, Default Value: 0

Setting Description
0 Eco Mode Off
255 Eco Mode on

Parameter 3: Auto-Relock Time

10 to 180 seconds default is 30 seconds
Size: 1 Byte, Default Value: 30

Setting Description
10 - 180 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Wrong Code Entry Limit

Parameter 5: Language

1=English, 2=Spanish, 3=French default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English
2 Spanish
3 French

Parameter 7: Shut Down Time (After wrong codes)

10 to 180 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 180 Seconds

Parameter 8: Operating Mode

00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode
1 Vacation Mode
2 Privacy Mode

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 1.78:32.33
Z-Wave Version 6.51.07
Certification ID ZC10-22067100
Z-Wave Product Id 0x0129.0x8103.0x12D4
Door Lock Type
Firmware Updatable
IP (Ingress Protection) Rated ok
Outdoor Use ok
Sensors
Supported Notification Types
Frequency XXfrequency
Maximum transmission power XXantenna
Door Lock - Keypad