This is a
Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique pin codes for friends and family and remove codes whenever you need to. This Yale Real Living lock features Z-Wave Plus technology and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave Plus automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use!
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Level control, 1 = High Volume, 2 = Low Volume, 3 =Silent. Default is 2 or Low Volume Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 3 | Sound level |
0x00 = OFF, 0xFF = ON default is 0xFF or ON. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | One Touch Locking Off |
255 | One Touch Locking On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Privacy Button Off |
255 | Privacy Button On |
0x00 = OFF , 0xFF=ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Lock Status LED Off |
255 | Lock Status LED On |
01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset to Factory Off |
255 | Reset to Factory ON |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFEnables the Escape Return mode of operation for thelock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Escape Return Off |
255 | Escape Return On |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Relock On |
255 | Auto Relock OFF |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode ofoperation with reduced sound and led brightness. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Eco Mode Off |
255 | Eco Mode on |
10 to 180 seconds default is 30 seconds Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 180 | Seconds |
3 to 10 default is 5 times Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 10 | Wrong Code Entry Limit |
1=English, 2=Spanish, 3=French default is 1= English Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
10 to 180 seconds default is 60 seconds Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 180 | Seconds |
00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal Mode |
1 | Vacation Mode |
2 | Privacy Mode |
Hardware Platform | ZM5101 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.78:32.33 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22067100 |
Z-Wave Product Id | 0x0129.0x8103.0x12D4 |
Door Lock Type | |
Firmware Updatable | |
IP (Ingress Protection) Rated | ok |
Outdoor Use | ok |
Sensors | |
Supported Notification Types | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |