Quickstart

This is a secure Thermostat - HVAC for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The HE-FT01 is HELTUNs advanced programmable Z-Wave thermostat for heating/cooling systems such as fan coil units, floor convectors, and wall, window, or ceiling mounted air conditioning units. The HE-FT01 thermostat is impossibly thin on the wall while still being packed full of features, delivering highly accurate comfort control through proprietary technology and four built-in sensors. You can monitor and control the HE-FT01 from anywhere in the world using a Z-Wave hub and your smartphone.* And because it uses Z-Wave Plus version 2, Smart Start, S2 Security and 700 platform technologies, the HE-FT01 can be placed up to 100 meters away from the hub and is a snap to install. Best of all, the built-in Power Consumption System precisely monitors how much energy you used during any particular day, week or month, helping you save money on energy costs while staying comfortable all year long.The HELTUN HE-FT01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living. (*hub and smartphone not included)

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 This is the Lifeline Group 1 which sends status (lifeline) reports to the primary controller.
2 1 Fan Low Speed (OUT-1) is used to turn the associated devices on/off reflecting OUT-1 operation.
3 1 Fan Medium Speed (OUT-2) is used to turn the associated devices on/off reflecting OUT-2 operation.
4 1 Fan High Speed (OUT-3) is used to turn the associated devices on/off reflecting OUT-3 operation.
5 1 Heater (OUT-4) is used to turn the associated devices on/off reflecting OUT-4 operation.
6 1 Cooler (OUT-5) is used to turn the associated devices on/off reflecting OUT-5 operation.

Configuration Parameters

Parameter 1: TIME CORRECTION

Time correction by controller
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off auto-correction
1 - 0 If thermostat is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway

Parameter 10: MANUAL BRIGHTNESS

Display manual brightness level.The Display Brightness Level Parameter will take effect when Parameter 22 is set to Manual Control (value = 0). Note: The environment illumination is displayed in the TIME position and also can be checked at any time via a Z-Wave gateway.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 15 The LCD brightness may be adjusted from 1 (lowest brightness) to 15 (highest brightest).

Parameter 11: TOUCH THRESHOLD

Touch buttons sensitivity. 5 = Highly sensitive. 50 = Lowest sensitivity. Note: Setting the sensitivity too high can lead to false touch detection. We recommend not changing this Parameter unless there is a need to do so.
Size: 1 Byte, Default Value: 15

Setting Description
5 - 50 Threshold to be adjusted from level 5 (very sensitive) to 50 (minimal sensitivity).

Parameter 12: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 13: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 14: BASIC SET MODE

Mode to switch to on Basic Set Action command This Parameter defines which Operating Mode the HE-FT01 reverts to if the Basic Set command is received. If the Basic Set command value is 0 (OFF state) the HE-FT01 will go to OFF mode and switch the operating state to IDLE. If the Basic Set command value is 0xFF (ON state) the HE-FT01 will change the Mode to the corresponding Parameter value.
Size: 1 Byte, Default Value: 2

Setting Description
0 No action
1 - 0 COM with Heating & Cooling Climate Mode
2 - 0 COM with Heating Climate Mode
3 - 0 COM with Cooling Climate Mode
4 - 0 TIME with Heating & Cooling Climate Mode
5 - 0 TIME with Heating Climate Mode
6 - 0 TIME with Cooling Climate Mode
7 - 0 ECO with Heating Climate Mode
8 - 0 ECO with Cooling Climate Mode
9 - 0 Ventilation Climate Mode

Parameter 15: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 16: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 17: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 18: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 19: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 2: TIME FORMAT

Time format
Size: 1 Byte, Default Value: 1

Setting Description
0 24 hour format
1 - 0 12 hour (AM/PM) format

Parameter 20: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 21: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 22: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 23: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 24: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 25: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 26: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 27: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 28: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 29: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 3: WEEKDAY

Week day. This parameter allows manually adjustment of the day of the week in case if the thermostat is not connected to any Z-Wave gateway or Parameter 09 (auto-correction) is selected as 0.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 0 Monday
2 - 0 Tuesday
3 - 0 Wednesday
4 - 0 Thursday
5 - 0 Friday
6 - 0 Saturday
7 - 0 Sunday

Parameter 30: RESERVED

Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter 31: SENSORS REPORT TIME

Sensors consecutive reporting interval, minutes.When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its room & floor temperature, humidity and light sensors even if there are not changes in the values. This Parameter defines the interval between consecutive reports. The value can be adjusted from 1 min to 120 min.Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. We recommend to reduce the value of this parameter only in case of poor connection, when reports from the device does not always reach the gateway.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 120 The value can be adjusted from 1 to 120 minutes

Parameter 32: CONSUMPTION REPORT TIME

This Parameter defines the interval (in minutes) between consecutive reports of real time and cumulative energy consumption data to the gateway. The value can be adjusted from 1 min to 120 min. The factory default value is 10 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order to not increase traffic on your network, we recommend not reducing this value.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 120 Consumption meter consecutive reporting interval in minutes.

Parameter 33: TEMPERATURE THRESHOLD

Temperature difference to send to controller, value x10. This parameter determines the change in temperature level (in C) resulting in temperature sensors report being sent to the gateway. The value of this parameter should be x10, e.g. for 0.4C use value 40. From 0.5C to 10C can be selected. The factory default value is 0.5C (5).
Size: 1 Byte, Default Value: 5

Setting Description
0 Stop sending the reports
5 - 100 Temperature level difference (in C), value x10.

Parameter 34: HUMIDITY THRESHOLD

This parameter determines the percentage change in relative humidity level which will trigger a report being sent to the gateway. From 2% to 25% can be selected.
Size: 1 Byte, Default Value: 2

Setting Description
0 Stop sending the reports
2 - 25 Humidity level difference in %

Parameter 35: LIGHT THRESHOLD

This parameter determines the change in the ambient illumination level that will trigger a report being sent to the gateway.
Size: 1 Byte, Default Value: 50

Setting Description
0 Stop sending the reports
10 - 99 Light sensor values difference

Parameter 36: OUT1 LOAD

Power of the Relay 1 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 5000 Power of the Relay 1 load in W

Parameter 37: OUT-2 LOAD

Power of the Relay 2 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 5000 Power of the Relay 2 load in W

Parameter 38: OUT3 LOAD

Power of the Relay 3 load in W.It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 5000 Power of the Relay 3 load in W

Parameter 39: OUT4 LOAD

Power of the Relay 4 load in W.It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 5000 Power of the Relay 4 load in W

Parameter 4: HOUR

This Parameter allows manual adjustment of Time in hours (24 hours).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 23 Manual adjustment of time hours (24 hours).

Parameter 40: OUT5 LOAD

Power of the Relay 5 load in W.It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 5000 Power of the Relay 5 load in W

Parameter 41: TIME MODE OPERATION

This parameter determines the Climate Mode (Heating or Cooling) to which HE-FT01 will switch when the TIME operating mode is selected.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 0 The thermostat will go to Heating & Cooling mode
2 - 0 The thermostat goes to Heating mode
3 - 0 The thermostat goes to Cooling Mode

Parameter 42: MORNING START TIME

Morning start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
Size: 2 Byte, Default Value: 600

Setting Description
0 - 2359 Morning start time. Format: HHMM (from 00:00 to 23:59)

Parameter 43: DAY START TIME

Day start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
Size: 2 Byte, Default Value: 900

Setting Description
0 - 2359 Day start time. Format: HHMM (from 00:00 to 23:59)

Parameter 44: EVENING START TIME

Evening start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
Size: 2 Byte, Default Value: 1800

Setting Description
0 - 2359 Evening start time. Format: HHMM (from 00:00 to 23:59)

Parameter 45: NIGHT START TIME

Night start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
Size: 2 Byte, Default Value: 2300

Setting Description
0 - 2359 Night start time. Format: HHMM (from 00:00 to 23:59)

Parameter 46: MONDAY MORNING TEMP

Monday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Monday Morning temperature value

Parameter 47: MONDAY DAYTIME TEMP

Monday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Monday Day temperature value

Parameter 48: MONDAY EVENING TEMP

Monday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Monday Evening temperature value

Parameter 49: MONDAY NIGHT TEMP

Monday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Monday Night temperature value

Parameter 5: MINUTE

This Parameter allows manual adjustment of the Time in minutes (60 minutes))
Size: 1 Byte, Default Value: 0

Setting Description
0 - 59 Manual adjustment of time minutes (60 minutes)

Parameter 50: TUESDAY MORNING TEMP

Tuesday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Tuesday Morning temperature value

Parameter 51: TUESDAY DAYTIME TEMP

Tuesday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Tuesday Day temperature value

Parameter 52: TUESDAY EVENING TEMP

Tuesday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Tuesday Evening temperature value

Parameter 53: TUESDAY NIGHT TEMP

Tuesday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Tuesday Night temperature value

Parameter 54: WEDNESDAY MORNING TEMP

Wednesday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Wednesday Morning temperature value

Parameter 55: WEDNESDAY DAYTIME TEMP

Wednesday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Wednesday Day temperature value

Parameter 56: WEDNESDAY EVENING TEMP

Wednesday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Wednesday Evening temperature value

Parameter 57: WEDNESDAY NIGHT TEMP

Wednesday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Wednesday Night temperature value

Parameter 58: THURSDAY MORNING TEMP

Thursday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Thursday Morning temperature value

Parameter 59: THURSDAY DAYTIME TEMP

Thursday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Thursday Day temperature value

Parameter 6: DEGREE MODE

Degree mode (C/F)Floor and air temperature, as well as Set Point and all Parameters will be indicated in the chosen mode. Factory default value is degrees Celsius (0).
Size: 1 Byte, Default Value: 0

Setting Description
0 Celsius
1 - 0 Fahrenheit

Parameter 60: THURSDAY EVENING TEMP

Thursday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Thursday Evening temperature value

Parameter 61: THURSDAY NIGHT TEMP

Thursday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Thursday Night temperature value

Parameter 62: FRIDAY MORNING TEMP

Friday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Friday Morning temperature value

Parameter 63: FRIDAY DAYTIME TEMP

Friday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Friday Day temperature value

Parameter 64: FRIDAY EVENING TEMP

Friday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Friday Evening temperature value

Parameter 65: FRIDAY NIGHT TEMP

Friday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Friday Night temperature value

Parameter 66: SATURDAY MORNING TEMP

Saturday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Saturday Morning temperature value

Parameter 67: SATURDAY DAYTIME TEMP

Saturday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Saturday Day temperature value

Parameter 68: SATURDAY EVENING TEMP

Saturday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Saturday Evening temperature value

Parameter 69: SATURDAY NIGHT TEMP

Saturday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Saturday Night temperature value

Parameter 7: AIR TEMP CORRECTION

This Parameter defines the offset value for room air temperature. If the internal air temperature sensor is not correctly calibrated, then manual calibration can be accomplished by adjusting the values up to 9.5C (17F). This value will be added or subtracted from the internal air temperature sensor reading.
Size: 1 Byte, Default Value: 0

Setting Description
-95 - 95 Air temperature offset value (C x 10)

Parameter 70: SUNDAY MORNING TEMP

Sunday Morning temperature, valueX10
Size: 2 Byte, Default Value: 240

Setting Description
40 - 370 Sunday Morning temperature value

Parameter 71: SUNDAY DAYTIME TEMP

Sunday Day temperature, valueX10
Size: 2 Byte, Default Value: 200

Setting Description
40 - 370 Sunday Day temperature value

Parameter 72: SUNDAY EVENING TEMP

Sunday Evening temperature, valueX10
Size: 2 Byte, Default Value: 230

Setting Description
40 - 370 Sunday Evening temperature value

Parameter 73: SUNDAY NIGHT TEMP

Sunday Night temperature, valueX10
Size: 2 Byte, Default Value: 180

Setting Description
40 - 370 Sunday Night temperature value

Parameter 8: TEMP HYSTERESYS

This Parameter defines the hysteresis value for temperature control. The HE-FT01 will stabilize the temperature with the selected hysteresis. For example, if the SET POINT is set for 25C and HYSTERESIS is set for 0.5C, the HE-FT01 will change the state to IDLE if the temperature reaches 25.0C. It will change the state to HEATING if the temperature becomes lower than 24.5C, and will change the state to COOLING if the temperature rises beyond 25.5C. The hysteresis value can be changed from 0.2C to 10.0C range in Celsius mode, and 0.3F to 18.0F in Fahrenheit. The factory-default value is 0.5C (0.9F).
Size: 1 Byte, Default Value: 5

Setting Description
2 - 100 Temperature hysteresis value (C x 10)

Parameter 9: AUTO BRIGHTNESS

Display auto-brightness controlThe HE-FT01 can adjust its display brightness automatically depending on the ambient room brightness.
Size: 1 Byte, Default Value: 1

Setting Description
0 Manual Control: Inactive Level brightness will be set to the level defined by Parameter 10.
1 - 0 Automatic Brightness Control.

Technical Data

Hardware Platform ZGM130
Device Type Thermostat - HVAC
Network Operation Always On Slave
Firmware Version HW: 20 FW: 2.01
Z-Wave Version 7.11.1
Certification ID ZC12-20010025
Z-Wave Product Id 0x0344.0x0004.0x0002
Neutral Wire Required ok
Firmware Updatable Updatable by Consumer by RF
Thermostat HVAC Systems Supported Cool OnlyHeat OnlyMulti StageVentilation Control
Thermostat Modes AutoAuto ChangeoverCoolEnergy Save CoolEnergy Save HeatFan OnlyHeat
Thermostat Power Source Mains powered (120V/240V)Power Stealing (hard-wired 24V)
Switch Type Dry Contact
Frequency XXfrequency
Maximum transmission power XXantenna
Thermostat - HVAC