This is a
The HELTUN HE-RS01 is an advanced programmable Z-Wave Plus v2 in-wall relay switch that controls many devices, including lights, dimmers, blinds, curtains, door locks, gates, motorized valves, roller shutters, and more. Features: Five-channel 5-amp relays with dry contact inputs Each relay may be controlled by a timer or on a week schedule Power Consumption logicmonitors energy usage 10 association groups Incorporates HELTUN Advanced Zero-Cross TechnologyThe HELTUN HE-RS01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | This is the Lifeline Group 1 which sends status (lifeline) reports to the primary controller. |
2 | 1 | Group 2External Input S1 Basic Set: is assigned to Input S1 state and will be triggered when the button on switch connected to S1 input was pressed. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
3 | 1 | Group 3External Input S1 Multilevel Set: is assigned to Input S1. It sends MULTILEVEL SWITCH command class frame when the button on switch connected to S1 input was held. Is used to send UP/DOWN command to the associated devices. The group supports one Node. |
4 | 1 | Group 4External Input S2 Basic Set: is assigned to Input S2 state and will be triggered when the button on switch connected to S2 input was pressed. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
5 | 1 | Group 5External Input S2 Multilevel Set: is assigned to Input S2. It sends MULTILEVEL SWITCH command class frame when the button on switch connected to S2 input was held. Is used to send UP/DOWN command to the associated devices. |
6 | 1 | Group 6External Input S3 Basic Set: is assigned to Input S3 state and will be triggered when the button on switch connected to S3 input was pressed. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
7 | 1 | Group 7External Input S3 Multilevel Set: is assigned to Input S3. It sends MULTILEVEL SWITCH command class frame when the button on switch connected to S3 input was held. Is used to send UP/DOWN command to the associated devices. |
8 | 1 | Group 8External Input S4 Basic Set: is assigned to Input S4 state and will be triggered when the button on switch connected to S4 input was pressed. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
9 | 1 | Group 9External Input S4 Multilevel Set: is assigned to Input S4. It sends MULTILEVEL SWITCH command class frame when the button on switch connected to S4 input was held. Is used to send UP/DOWN command to the associated devices. |
10 | 1 | Group 10External Input S5 Basic Set: is assigned to Input S5 state and will be triggered when the button on switch connected to S5 input was pressed. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
11 | 1 | Group 11External Input S5 Multilevel Set: is assigned to Input S5. It sends MULTILEVEL SWITCH command class frame when the button on switch connected to S5 input was held. Is used to send UP/DOWN command to the associated devices. |
12 | 1 | Group 12Relay 1 Basic Set: is assigned to relay N1 and will be triggered on the relay state change. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
13 | 1 | Group 13Relay 2 Basic Set: is assigned to relay N2 and will be triggered on the relay state change. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
14 | 1 | Group 14Relay 3 Basic Set: is assigned to relay N3 and will be triggered on the relay state change. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
15 | 1 | Group 15Relay 4 Basic Set: is assigned to relay N4 and will be triggered on the relay state change. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
16 | 1 | Group 16Relay 5 Basic Set: is assigned to relay N5 and will be triggered on the relay state change. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. |
Time correction by controller Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Switch off auto-correction |
1 - 0 | If TPS05 is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway |
Relay 5 control source Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Controlled by gateway or associated device |
1 | Controlled by touch button N1 (Top Left) |
2 | Controlled by touch button N2 (Top Right) |
3 | Controlled by touch button N3 (Bottom Left) |
4 | Controlled by touch button N4 (Bottom Right) |
5 | Controlled by touch button N5 (Center) |
Hold control mode for touch button 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Hold function is disabled |
1 | Operate like click |
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). |
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). |
Hold control mode for touch button 2 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Hold function is disabled |
1 | Operate like click |
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). |
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). |
Hold control mode for touch button 3 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Hold function is disabled |
1 | Operate like click |
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). |
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). |
Hold control mode for touch button 4 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Hold function is disabled |
1 | Operate like click |
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). |
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). |
Hold control mode for touch button 5 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Hold function is disabled |
1 | Operate like click |
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). |
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). |
Click control mode for touch button 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Click function disabled |
1 | Relay inverts state (toggles ON to OFF, OFF to ON). |
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. |
3 | Relay switches to ON state only. |
4 | Relay switches to OFF state only. |
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. |
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. |
Click control mode for touch button 2 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Click function disabled |
1 | Relay inverts state (toggles ON to OFF, OFF to ON). |
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. |
3 | Relay switches to ON state only. |
4 | Relay switches to OFF state only. |
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. |
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. |
Click control mode for touch button 3 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Click function disabled |
1 | Relay inverts state (toggles ON to OFF, OFF to ON). |
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. |
3 | Relay switches to ON state only. |
4 | Relay switches to OFF state only. |
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. |
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. |
Click control mode for touch button 4 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Click function disabled |
1 | Relay inverts state (toggles ON to OFF, OFF to ON). |
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. |
3 | Relay switches to ON state only. |
4 | Relay switches to OFF state only. |
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. |
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. |
The day of the week (starting from Monday) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 0 | Monday |
2 - 0 | Tuesday |
3 - 0 | Wednesday |
4 - 0 | Thursday |
5 - 0 | Friday |
6 - 0 | Saturday |
7 - 0 | Sunday |
Click control mode for touch button 5 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Click function disabled |
1 | Relay inverts state (toggles ON to OFF, OFF to ON). |
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. |
3 | Relay switches to ON state only. |
4 | Relay switches to OFF state only. |
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. |
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. |
Timer mode duration for button 1.This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 30).Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time.The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to 0 it will operate as a short contact (about 0.5 sec). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | Timer mode duration in seconds |
Timer mode duration for button 2.This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 31).Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time.The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to 0 it will operate as a short contact (about 0.5 sec). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | Timer mode duration in seconds |
Timer mode duration for button 3.This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 32).Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time.The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to 0 it will operate as a short contact (about 0.5 sec). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | Timer mode duration in seconds |
Timer mode duration for button 4.This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 33).Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time.The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to 0 it will operate as a short contact (about 0.5 sec). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | Timer mode duration in seconds |
Timer mode duration for button 5.This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 34).Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time.The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to 0 it will operate as a short contact (about 0.5 sec). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | Timer mode duration in seconds |
Group 1 relay inverse mode.The valid values are the following:0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35,41, 42, 43, 45, 51, 52, 53, 54 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Inverse function is disabled |
12 - 0 | Relays N1 and N2 will operate in inverse mode. |
13 - 0 | Relays N1 and N3 will operate in inverse mode. |
14 - 0 | Relays N1 and N4 will operate in inverse mode. |
15 - 0 | Relays N1 and N5 will operate in inverse mode. |
21 - 0 | Relays N2 and N1 will operate in inverse mode. |
23 - 0 | Relays N2 and N3 will operate in inverse mode. |
24 - 0 | Relays N2 and N4 will operate in inverse mode. |
25 - 0 | Relays N2 and N5 will operate in inverse mode. |
31 - 0 | Relays N3 and N1 will operate in inverse mode. |
32 - 0 | Relays N3 and N2 will operate in inverse mode. |
34 - 0 | Relays N3 and N4 will operate in inverse mode. |
35 - 0 | Relays N3 and N5 will operate in inverse mode. |
41 - 0 | Relays N4 and N1 will operate in inverse mode. |
42 - 0 | Relays N4 and N2 will operate in inverse mode. |
43 - 0 | Relays N4 and N3 will operate in inverse mode. |
45 - 0 | Relays N4 and N5 will operate in inverse mode. |
51 - 0 | Relays N5 and N1 will operate in inverse mode. |
52 - 0 | Relays N5 and N2 will operate in inverse mode. |
53 - 0 | Relays N5 and N3 will operate in inverse mode. |
54 - 0 | Relays N5 and N4 will operate in inverse mode. |
Group 2 relay inverse mode.The valid values are the following:0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35,41, 42, 43, 45, 51, 52, 53, 54 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Inverse function is disabled |
12 - 0 | Relays N1 and N2 will operate in inverse mode. |
13 - 0 | Relays N1 and N3 will operate in inverse mode. |
14 - 0 | Relays N1 and N4 will operate in inverse mode. |
15 - 0 | Relays N1 and N5 will operate in inverse mode. |
21 - 0 | Relays N2 and N1 will operate in inverse mode. |
23 - 0 | Relays N2 and N3 will operate in inverse mode. |
24 - 0 | Relays N2 and N4 will operate in inverse mode. |
25 - 0 | Relays N2 and N5 will operate in inverse mode. |
31 - 0 | Relays N3 and N1 will operate in inverse mode. |
32 - 0 | Relays N3 and N2 will operate in inverse mode. |
34 - 0 | Relays N3 and N4 will operate in inverse mode. |
35 - 0 | Relays N3 and N5 will operate in inverse mode. |
41 - 0 | Relays N4 and N1 will operate in inverse mode. |
42 - 0 | Relays N4 and N2 will operate in inverse mode. |
43 - 0 | Relays N4 and N3 will operate in inverse mode. |
45 - 0 | Relays N4 and N5 will operate in inverse mode. |
51 - 0 | Relays N5 and N1 will operate in inverse mode. |
52 - 0 | Relays N5 and N2 will operate in inverse mode. |
53 - 0 | Relays N5 and N3 will operate in inverse mode. |
54 - 0 | Relays N5 and N4 will operate in inverse mode. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Time Hour Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 23 | Time Hour in 24 hour format |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Relays control by sensors Group 10, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 20, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 30, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 40, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 50, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 60, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 7.0, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 80, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Relays control by sensors Group 90, 1000000053112359Encoded as 8 digit value (ABCDEFGH):A: Relay number (1.. 5)B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor,2-Light Sensor, 3-Time control)C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than)D: State Change, 0- Switch OFF, 1- Switch ONEFGH: Condition ValueSensor Value for Control modes 0-2Time Of Day for Control mode 3.EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Time Minute Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | Manual adjustment of time minutes (60 minutes) |
Relays control by sensors Group 10. 0, 1000000053112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Scenario function is disabled |
1 - 53112359 | Behavior according to the encoded scenario |
Power load consumption (in Watts) Relay channel 1 in order to calculate total energy consumption relative to the time each relay is ON. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1100 | Power load consumption (in Watts) |
Power load consumption (in Watts) Relay channel 2 in order to calculate total energy consumption relative to the time each relay is ON. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1100 | Power load consumption (in Watts) |
Power load consumption (in Watts) Relay channel 3 in order to calculate total energy consumption relative to the time each relay is ON. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1100 | Power load consumption (in Watts) |
Power load consumption (in Watts) Relay channel 4 in order to calculate total energy consumption relative to the time each relay is ON. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1100 | Power load consumption (in Watts) |
Power load consumption (in Watts) Relay channel 5 in order to calculate total energy consumption relative to the time each relay is ON. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1100 | Power load consumption (in Watts) |
Associations mode for external input S1 .These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On each hold event, UP (brighten) and DOWN (dim) command will be alternately sent to associated devices. |
1 - 0 | On each hold event, the UP (brighten) command will be sent to associated devices. |
2 - 0 | On each hold event, the DOWN (dim) command will be sent to associated devices. |
Associations mode for external input S2.These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On each hold event, UP (brighten) and DOWN (dim) command will be alternately sent to associated devices. |
1 - 0 | On each hold event, the UP (brighten) command will be sent to associated devices. |
2 - 0 | On each hold event, the DOWN (dim) command will be sent to associated devices. |
Associations mode for external input S3.These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On each hold event, UP (brighten) and DOWN (dim) command will be alternately sent to associated devices. |
1 - 0 | On each hold event, the UP (brighten) command will be sent to associated devices. |
2 - 0 | On each hold event, the DOWN (dim) command will be sent to associated devices. |
Associations mode for external input S4.These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On each hold event, UP (brighten) and DOWN (dim) command will be alternately sent to associated devices. |
1 - 0 | On each hold event, the UP (brighten) command will be sent to associated devices. |
2 - 0 | On each hold event, the DOWN (dim) command will be sent to associated devices. |
Energy Consumption Meter Consecutive Report Interval, minutes Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 120 | Energy Consumption Meter Consecutive Report Interval in Minutes |
Associations mode for external input S5.These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On each hold event, UP (brighten) and DOWN (dim) command will be alternately sent to associated devices. |
1 - 0 | On each hold event, the UP (brighten) command will be sent to associated devices. |
2 - 0 | On each hold event, the DOWN (dim) command will be sent to associated devices. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Relay 1 control source Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Controlled by gateway or associated device |
1 | Controlled by touch button N1 (Top Left) |
2 | Controlled by touch button N2 (Top Right) |
3 | Controlled by touch button N3 (Bottom Left) |
4 | Controlled by touch button N4 (Bottom Right) |
5 | Controlled by touch button N5 (Center) |
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. |
Relay 2 control source Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Controlled by gateway or associated device |
1 | Controlled by touch button N1 (Top Left) |
2 | Controlled by touch button N2 (Top Right) |
3 | Controlled by touch button N3 (Bottom Left) |
4 | Controlled by touch button N4 (Bottom Right) |
5 | Controlled by touch button N5 (Center) |
Relay 3 control source Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Controlled by gateway or associated device |
1 | Controlled by touch button N1 (Top Left) |
2 | Controlled by touch button N2 (Top Right) |
3 | Controlled by touch button N3 (Bottom Left) |
4 | Controlled by touch button N4 (Bottom Right) |
5 | Controlled by touch button N5 (Center) |
Relay 4 control source Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | Controlled by gateway or associated device |
1 | Controlled by touch button N1 (Top Left) |
2 | Controlled by touch button N2 (Top Right) |
3 | Controlled by touch button N3 (Bottom Left) |
4 | Controlled by touch button N4 (Bottom Right) |
5 | Controlled by touch button N5 (Center) |
Hardware Platform | ZGM130 |
Device Type | Central Scene Device |
Network Operation | Always On Slave |
Firmware Version | HW: 76 FW: 1.01 |
Z-Wave Version | 7.11.1 |
Certification ID | ZC12-20040046 |
Z-Wave Product Id | 0x0344.0x0004.0x0009 |
Z-Wave Scene Type | Central Scene |
Switch Type | Dry Contact |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |