Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Ring Alarm Contact Sensor is a wireless sensor for the Ring Alarm system which provides users the ability to know when a door or window is open or closed. After installing the sensor on a door or window and setting up the sensor in the Ring app, monitor and receive notifications when the door or window opens or closes. The Ring Alarm Base Station is required to enable Contact Sensor features and functions within the Ring app.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 This is the Lifeline group and the following are the supported Command Classes-1.Notification Reporta.See notification CC section for notifications that are sent2.Battery Report3.Device Reset Locally Notification

Configuration Parameters

Parameter 1: Heartbeat Interval

Heartbeats are automatic battery reports on a timer after the last event.
Size: 1 Byte, Default Value: 70

Setting Description
1 - 70 This parameter is the number of minutes between heartbeats.

Parameter 2: Application Retriess

Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 5 This parameter is the number of application level retries.

Parameter 3: Application Level Retry Base Wait Time Period

The number base seconds used in the calculation for sleeping between retry messages.
Size: 1 Byte, Default Value: 5

Setting Description
1 - 96 This parameter is the number base seconds used in the calculation for sleeping between retry messages.

Parameter 4: LED Indicator Enable

This parameter allows a user, via software, to configure the various LED indications on the device.0 == Don't show green1 == Show green after Supervision Report Intrusion (Fault)2 == Show green after Supervision Report both Intrusion and Intrusion clear
Size: 1 Byte, Default Value: 1

Setting Description
0 - 2 This parameter is used to configure the various LED indications on the device.

Parameter 5: One Shot Timer

Writing to this parameter prompts the sensor to send a wakeup notification one time after this parameter's number of seconds. After which it is reset back to 0.
Size: 2 Byte, Default Value: 0

Setting Description
5 - 65535 This parameter prompts the sensor to send a wakeup notification.

Parameter 6: Supervisory Report Timeout

The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.
Size: 2 Byte, Default Value: 1500

Setting Description
500 - 5000 This parameter is the number of milliseconds waiting for a Supervisory Report response to a Supervisory Get.

Technical Data

Hardware Platform EFR32Z
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.10
Z-Wave Version 7.12.2
Certification ID ZC12-20050058
Z-Wave Product Id 0x0346.0x0201.0x0301
Color White
Frequency XXfrequency
Maximum transmission power XXantenna