This is a
The Water Sensor 7 pro brings more safety into your home. With its flexible sensor probe and the sensitive sensor point it detects the presence and absence of water at any given location. Furthermore the Watersensor 7 pro is enabled to accurately measure the temperature and humidity of its environment, so you are always informed about your room climate. Thanks to the latest Z-Wave 700 series technology, the Water Sensor 7 is distinguished with and increased range, S2 Security, OTA FW update and SmartStart.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline association to gateways |
2 | 5 | Control devices when water leakage is detected |
3 | 5 | Sends out alarm message when water leakage is detected |
4 | 5 | Sends out alarm messages when tamper is tripped |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Time a tamper alarm is delayed. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
This parameter defines if the alarm cancellation event is reported. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Do not send Report |
1 - 0 | Send Report |
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline.If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 18, may still be active. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | Disabled |
1 - 100 | 1/10 degree |
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline.If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 18, may still be active. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Disabled |
1 - 20 | % |
This parameter defines the time interval to send an unsolicited report.If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active. Size: 2 Byte, Default Value: 43200
Setting | Description |
---|---|
0 | Disabled |
900 - 65535 | Seconds |
This parameter helps reset configuration parameters and the device to factory defaults1 - 1431655764 (0x55555554) - Reset all Parameter settings to their default settings.1431655765 - Completely factory reset sensor and send device reset locally notification. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1431655764 | Reset all Parameter settings to their default settings. |
1431655765 | Completely factory reset sensor and send device reset locally notification. |
This parameter defines when LEDs will indicate events. Disabling all indications may extend battery life.Value 0 means - No Indications. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
1 - 0 | Water Leakage Status Change |
2 - 0 | Wake Up |
4 - 0 | Device Tampering |
7 - 0 | All LED indications on (values 1 + 2 + 4 summarized) |
3 - 0 | Water Leakage Status Change + Wake Up (values 1 + 2) |
5 - 0 | Water Leakage Status Change + Device Tampering (values 1 + 4) |
6 - 0 | Wake Up + Device Tampering (values 2 + 4) |
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 - 0 | Enabled |
This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Water Leakage Start and Stop |
1 - 0 | Switch after Water Leakage Start and Stop |
2 - 0 | Switch after Water Leakage Start and Stop |
This parameter defines which commands is sent to 2nd Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 - 0 | Off |
2 - 0 | On and Off |
This is the BASIC command value sent in case of u0022Onu0022 event. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
This is the BASIC command value sent in case of u0022Offu0022 event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
On command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 0.00 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20060068 |
Z-Wave Product Id | 0x0371.0x0002.0x0013 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |