Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Strips Guard is an ultra-thin contact sensor and the thinnest magnet sensor in the world, detecting if your doors or windows are open or closed and featuring a design so sleek it disappears right into the architecture of any installation scenario.Strips Guard sends an alarm signal if it detects the opening of any door or window and due to its slim and discrete design, can also be placed in cabinets, on drawers or even behind artwork as an activity sensor. Its unique design allows it to be easily placed almost anywhere, generally in most places where other sensors simply cant fit.Strips Guard is an extremely reliable contact sensor. The unique design makes it easy to place nearly invisibly in your home to alert occupants of any open/close or activity event when connected to your Z-Wave smart home system.Strips 700 Series Guard can be used both indoors and out, and the integrated custom battery gives Strips an expected lifetime of 10+ years. For you, this means no hassles with changing or charging batteries in your Strips sensors for the lifetime of the product!Z-Wave Plus 700 series sensors bring a wealth of additional valued features such as longer range, low power consumption for extended battery life and SmartStart technology for instant enrolling. With SmartStart, device inclusion can be initiated automatically by simply removing the included magnets. The Z-Wave gateway then performs the inclusion process in the background without the need for user interaction. 700 Series provides a direct range of 100 meters, an improvement of 60 meters over the 500 series and also includes the industrys best S2 security, providing Strips Guard with the ultimate combination of features to securely protect your home.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Strips supports association group 1 (lifeline), max 1 node, normally used to send Stripsnotification to the Z-Wave controller.

Configuration Parameters

Parameter 1: Notification type

Select the notification type for the door and window open or close events.
Size: 1 Byte, Default Value: 1

Setting Description
0 Binary sensor report + Notification report (Access Control)
1 - 0 Notification report (Access Control)
2 - 0 Notification report (Home Security)

Parameter 15: Activate supervision

Activate Supervision command for onlyimportant alarm events or all events. Supervised commands require a confirmationfrom the gateway when a notification is received.
Size: 1 Byte, Default Value: 1

Setting Description
0 Events sent with S2 Encapsulation only
1 - 0 Only Door Open Alarm Report (Events sent with S2 and supervision encapsulation)
2 - 0 Unsolicited reports (Door Open/Close, Tamper clear, Wake-up notification and Battery Report events sent with S2 and supervision encapsulation)

Parameter 16: Supervision report wait time

Only used if parameter 22 is set to 1 (High security). The number of milliseconds to wait for a Supervision response when a Supervised message is sent.
Size: 2 Byte, Default Value: 10000

Setting Description
500 - 30000 (ms)

Parameter 17: No. of failed event retries

Only used if parameter 22 is set to 1 (High security). Number of retries when a confirmation is not received.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 5 0 = No retry, 1 - 5 = Number of retries when a confirmation is not received.

Parameter 18: Failed Event Retry Interval

Only used if parameter 22 is set to 1 (High security). The minimum number of seconds between retries.
Size: 1 Byte, Default Value: 6

Setting Description
1 - 60 Min = 1 second, Max = 60 seconds

Parameter 19: Heartbeat interval

Only used if parameter 22 is set to 1 (High security). Number of minutes between periodic battery reports (Heartbeats).
Size: 1 Byte, Default Value: 70

Setting Description
5 - 70 (mins) - Accepts multiples of 5 mins. - Any arbitary value in between 5 and 70 will be rounded up to a multiple of 5

Parameter 2: LED indication

Turn On or Off LED for specific event indications (ex. alarms).
Size: 1 Byte, Default Value: 1

Setting Description
0 Turns off LED for door open events
1 - 0 On

Parameter 22: Security Level

Select the level of security.
Size: 1 Byte, Default Value: 0

Setting Description
0 : Standard (Forces parameter behaviour as follows: #16=1000, #17=Sensative standard**, #18=0, #19=Off, #21=Off** Retries with an incrementally longer period until reconnected
1 - 0 : High Security (Enables parameters 16-19, 21)

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 6.20
Z-Wave Version 7.13.3
Certification ID ZC12-20120136
Z-Wave Product Id 0x019A.0x0004.0x0004
Outdoor Use ok
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor