Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Square D 15 Amp Z-Wave Switch Single Pole/3-WAY Energy Monitoring is the professionals choice for secure reliable lighting control. Sensitive enough to control the low wattage demands of a single LED yet as well as the demands of bright outdoor lighting.Perfect for monitoring energy usage in bedrooms where the switch controls the receptacles. It works with any Z-Wave hub and can be grouped with up to 5 other Z-Wave Plus devices.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline: Send device reset locally notificationStatusReport: On/Off status reportPowerReport: Power metering report
2 5 Sends Basic Set to associated devices,when press ON Button and OFF Button atsame time.

Configuration Parameters

Parameter 1: LED indicator Status

Synchronization of load power and LED indicator.
Size: 1 Byte, Default Value: 1

Setting Description
0 Power On, LED Off; Power Off, LED On
1 Power On, LED On;Power Off, LED Off

Parameter 2: Delayed OFF Time

Delay off means when users pressbutton to turn off the load,theres a reaction time.
Size: 1 Byte, Default Value: 0

Setting Description

Parameter 3: Power On Status

When the device is powered on, theinitial status.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 0 Off
2 - 0 On
3 - 0 Last State

Parameter 4: Child Lockout Enable

Child lockout feature can enabled anddisabled local control.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 - 0 Enable

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.17
Z-Wave Version 7.13.6
Certification ID ZC12-21030193
Z-Wave Product Id 0x0447.0x000E.0x1106
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch