Quickstart

This is a secure Window Covering DT for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller.This in-wall Roller Shutter Controller is a Z-Wave Plus TMenabled wireless device fully compatible with any Z-Wave TMenabled networks. This device is a security enabled Z-Wave Plus product that uses encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-Wave TMenabled devices displaying the Z-Wave TM logo can also be used with this device regardless of the manufacturer. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturer. Within the network it will act as repeater regardless of vender to increase reliability of the network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all functions. Its functionality and supported command classes is identical when included as a secure and non-secure device.The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway).

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 There is only one group called Lifelinethere is only 5 nodes for Group1 which sup-port MULTILEVEL_SWITCH_REPORTMETER_REPORT_COMMAND_V3 NOTI-FICATION_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN34 will report its instant power consumption every 1 hour to the node of Group 1. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour.
Size: 2 Byte, Default Value: 720

Setting Description
0 Disable auto Report
1 - 32767 5s~45 hour

Parameter 2: External switch mode

It is used to define the external button mode.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 0 One Push button
2 - 0 Two Push button

Parameter 3: Total moving time of curtain

This is a way for setting the total moving time of curtain manually.
Size: 2 Byte, Default Value: 0

Setting Description
0 The time depends on Moving Range Calibration
1 - 6000 0.1s~600s

Parameter 4: Watt threshold

The threshold is for PAN34 judging if the motor is running or not. The default value is 1 watts.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 5 The threshold is a judgment for motor running or not

Parameter 5: Watt differential

Whenever the watt value varies over 5%, PAN34 will send the meter report to group 1 nodes. The default value is 1 (5%).
Size: 1 Byte, Default Value: 1

Setting Description
0 It will not report Watt when change over 5%
1 - 0 It will report watt value when the differential is over 5%

Parameter 6: Timer offset for motor start running

This parameter is an offset to count for starting time of the motor. It will improve the inaccurate when moving to the middle position. The default value is 50.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 255 0s ~ 2.55s, 50 = 0.5s

Technical Data

Hardware Platform ZGM130
Device Type Window Covering DT
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01
Z-Wave Version 7.15.1
Certification ID ZC12-21070274
Z-Wave Product Id 0x013C.0x0001.0x0080
Color White
Firmware Updatable Updatable by Consumer by RF
Window Covering Control Features Automatic CalibrationPosition AwareSupports Open/Close Motion
Frequency XXfrequency
Maximum transmission power XXantenna
Window Covering DT