This is a
Aeotec MultiSensor 7 is aZ-Wave smart sensor. The corner of your room just got 6 times smarter. Its a motion sensor and its also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 6 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity,light, Ultraviolet and Vibration readings wherever MultiSensor 6 is installed. Those intelligent readings will equate to intelligent automation. And intelligent automation will give you the perfect smart home.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline. Device Reset Locally: When factory reset.Notification Report:See Notification Chapter for more information.Sensor Binary Report:See Param5 for more information.Sensor Multilevel Report:When sensors above over limit or below under limit.Battery Report:See Param101.Indicator Report:Issued when the indicator light changed |
2 | 5 | Basic Set Command will be sent to the associated device when motion trigger or untrigger. The basic set value is determined by Param11, Param12. See Param13 for more information. |
3 | 5 | Basic Set:When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64. |
4 | 5 | Basic Set:When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64. |
5 | 5 | Basic Set:When the current humidity is over or under the threshold set by Param14 |
6 | 5 | Basic Set:When the current humidity is under or over the threshold set by Param15 |
7 | 5 | Basic Set:When the current light/lux is over or under the threshold set by Param18 |
8 | 5 | Basic Set:When the current light/lux is under or over the threshold set by Param19. |
9 | 5 | Basic Set:When the current UV is over or under the threshold set by Param20 |
10 | 5 | Basic Set:When the current UV is under or over the threshold set by Param21 |
11 | 5 | Sensor Multilevel Report:When sensors above over limit or below under limit. |
Used to enable/disable beaming.If set to 1, FLiR commands will be supported. But the device must be re-included into the network to activate it.0 - disable1 - enable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 - 0 | Enable |
This value is Readonly. Used to report the power status (USB or Battery powered)0 - When battery powered, the device will act as RSS.1 - When USB cable insert, the device will act as LSS.The device must be re-included in the network to change the role type. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When battery powered, the device will act as RSS. |
1 - 0 | When USB cable insert, the device will act as LSS. |
Checklist 1 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param111. 1 - Battery16 - UV32 - Temperature64 - Humidity128 - Lux Size: 1 Byte, Default Value: 241
Setting | Description |
---|---|
1 - 0 | Battery |
16 - 0 | UV |
32 - 0 | Temperature |
64 - 0 | Humidity |
128 - 0 | Lux |
Checklist 2 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param112.1 - Battery16 - 32 - Temperature64 - Humidity128 - Lux Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 0 | Battery |
16 - 0 | UV. Other value descriptions, please see above description box of this parameter. |
Checklist 3 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param113. 1 - Battery16 - UV32 - Temperature64 - Humidity128 - Lux Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 0 | Battery. Other value descriptions, please see above description box of this parameter. |
Set control of other devices on group2 based on motion trigger.0 - Send BASIC_SET (0xFF) when motion is triggered to associated deviceSend BASIC_SET (0x00) when motion is untriggered to associated device1 - Send BASIC_SET (0x00) when motion is triggeredSend BASIC_SET (0xFF) when motion is untriggered2 - Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered.3 - Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered.4 - Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered.5 - Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered.6 - Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices.Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device |
1 - 0 | Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered |
2 - 0 | Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. |
3 - 0 | Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. |
4 - 0 | Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. |
5 - 0 | Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. |
6 - 0 | Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. |
Interval time set in seconds to check the checklist1s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Interval time set in seconds to check the checklist2s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Interval time set in seconds to check the checklist3s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger. Size: 2 Byte, Default Value: 65280
Setting | Description |
---|---|
0 - 65535 | Set Basic Set value for Group2. |
Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light Size: 2 Byte, Default Value: 30000
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux |
Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devices through group5. If measured humidity < (this value) send BASIC_SET (0x00) to associated devices through group5. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 100 | Set threshold of humidity. |
Set threshold of humidity. If measure humidity(this value) send BASIC_SET (0x00) to associated devices through group6. Size: 1 Byte, Default Value: 40
Setting | Description |
---|---|
0 - 100 | Set threshold of humidity. |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measuredtemperature >= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature<(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F. Size: 2 Byte, Default Value: 239
Setting | Description |
---|---|
-400 - 850 | Set threshold of temperature |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F. Size: 2 Byte, Default Value: 155
Setting | Description |
---|---|
-400 - 850 | Set threshold of temperature |
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux < (this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux. |
Set threshold of Light/Lux. If measured light/lux(this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux. |
Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3 will be reset. This setting value must always be less than timeout configuration.0 - disable1~3600 - timeout set in seconds Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
30 - 3600 | timeout set in seconds |
Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV < (this value) send BASIC_SET (0x00) to associated devices. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Set threshold of UV. |
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 200 | Temperature Offset Value |
Can add or minus this setting value to calibrate humidity when checked. Unit: %. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-100 - 100 | Humidity Offset Value |
Can add or minus this setting value to calibrate Lux when checked. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-10000 - 10000 | Lux Offset Value |
Can add or minus this setting value to calibrate UV when checked. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | Offset Value range -10-10. |
Set threshold of UV. If measured UV(this value) send BASIC_SET (0x00 to associated devices.) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 11 | Set threshold of UV. |
Timeout configuration set in second for motion sensor to send no trigger status. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
30 - 3600 | timeout set in seconds |
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
10 - 90 | Configure low battery report threshold |
Set the sensitivity of motion sensor.0 - disable1- minimum sensitivity11 - maximum sensitivity Size: 1 Byte, Default Value: 11
Setting | Description |
---|---|
0 | Disable |
1 - 11 | sensitivity range |
Enable/Disable threshold reporting, check time can be adjusted by Param45.0 - disable all threshold reports1 - enable all threshold reports Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable all threshold reports |
1 - 0 | enable all threshold reports |
Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 255 | Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. |
Humidity range = 1% to 50%, 0 = disable. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 50 | Humidity range = 1% to 50%, 0 = disable. |
0 = disable Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 - 10000 | Lux Threshold |
0 = disable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 11 | UV Threshold |
Set threshold check time in seconds if threshold is enable via Param40.1~65535 - When USB powered60~65535 - When Battery powered Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
1 - 65535 | Set threshold check time in seconds |
Eable/Disable alarm report for low temperature( Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 - 0 | Enable |
This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value.1 - Temperature upper level2 - Humidity upper level4 - Lux upper level8 - UV upper level16 - Temperature lower level32 - Humidity lower level64 - Lux lower level128 - UV lower level Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 0 | Temperature upper level |
2 - 0 | Humidity upper level |
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor. Size: 2 Byte, Default Value: 280
Setting | Description |
---|---|
-400 - 1000 | Set upper limit level for temperature |
Set which command class will be sent when motion sensor is triggered or detriggered.0 - Sends Notification Report1 - Sends Sensor Binary Report2 - Sends Notification and Sensor Binary Report Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Sends Notification Report |
1 - 0 | Sends Sensor Binary Report |
2 - 0 | Sends Notification and Sensor Binary Report |
Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-400 - 1000 | Set lower limit level for temperature |
Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) = (lower limit + recover limit), then temperature report. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
1 - 255 | Temperature recover limit set in scale of 0.1. |
Set humidity upper limit level. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 100 | Set humidity upper limit level. |
Set humidity lower limit level Size: 1 Byte, Default Value: 40
Setting | Description |
---|---|
0 - 100 | Set humidity lower limit level |
Set humidity recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 50 | Set humidity recover limit level |
Set lux upper limit level. Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 30000 | Set lux upper limit level. |
Set lux lower limit level. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 30000 | Set lux lower limit level. |
Set UV upper limit level. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 11 | Set UV upper limit level. |
Set UV lower limit level. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 11 | Set UV lower limit level. |
Used to enable/disable vibration sensor.0 - disable vibration1~254 - timeout set in minutes to reset vibration status255 - timeout set in minutes to reset vibration status Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | disable vibration |
1 - 254 | timeout set in minutes to reset vibration status |
255 | timeout set in minutes to reset vibration status |
Set UV recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 5 | Set UV recover limit level. |
This is read only and bit mask. Out of the limit state of sensors.Bit Mask:0 - within limit1 - out of limitValue:1 - Temperature upper level2 - Humidity upper level4 - Lux upper level8 - UV upper level16 - Temperature lower level32 - Humidity lower level64 - Lux lower level128 - UV lower level Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | within limit |
1 - 0 | Temperature upper level |
2 - 0 | Humidity upper level |
4 - 0 | Lux upper level |
Set the scale for temperature when reports.0 - Celsius1 - Fahrenheit Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
1 - 0 | Fahrenheit |
Set lux recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
1 - 255 | Set lux recover limit level. |
Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. If set to 0, do not report. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 0 | Enable |
Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this.0 - disable1 - enable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 - 0 | enable |
If LED is enabled by Param81, allow user to change the report color of motion sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Disable |
1 - 0 | Red |
2 - 0 | Blue |
3 - 0 | Green |
4 - 0 | Pink |
5 - 0 | Cyan |
6 - 0 | Purple |
7 - 0 | Orange |
8 - 0 | Yellow |
9 - 0 | White |
If LED is enabled by Param81, allow user to change the report color of temperature sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of humidity sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of Lux sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of UV sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of vibration sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of battery.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
If LED is enabled by Param81, allow user to change the report color of wakeup.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
Timeout set in seconds after Wakeup CC is send out before go to sleep. If wakeup no more information received, return to sleep mode immediately. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 - 255 | Timeout set in seconds |
If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway or other devices.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable. Other value descriptions, please see above description box of this parameter. |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-21080291 |
Z-Wave Product Id | 0x0371.0x0102.0x0018 |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |