Quickstart

This is a secure Lock DT for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Ness Z-Wave Door Lock Controller (DLC) is a unique access control accessory providing a smart relay output and door position sensor inputs.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5

Configuration Parameters

Parameter 1: The Relock Timer

Sets the output duration for the RELAY Output and the 12V Lock Output. Output ON duration in seconds. Range: 0 ~ 300. Default value: 10. 0 = Latching Operation.
Size: 2 Byte, Default Value: 10

Setting Description
0 0

Parameter 2: Function Options for Input Terminal SW1

Range: 0 ~ 3. Default: 2. Value = 0: The input is disabled. Value = 1: Normally Closed Door sensor. Value = 2: Normally Open Door sensor. Value = 3: External unlock pushbutton input (close circuit to unlock)
Size: 1 Byte, Default Value: 2

Setting Description
0 0

Parameter 3: Function Options for Input Terminal SW2

Range: 0 ~ 3. Default: 3. Value = 0: The input is disabled. Value = 1: Normally Closed Door sensor. Value = 2: Normally Open Door sensor. Value = 3: External unlock pushbutton input (close circuit to unlock)
Size: 1 Byte, Default Value: 3

Setting Description
0 0

Parameter 4: Battery Low setting

Reporting the battery low warning message when battery level reaches this value in percentage. Range: 10 ~ 50 (10% to 50%). Default: 10%
Size: 1 Byte, Default Value: 10

Setting Description
0 0

Parameter 5: Battery Scheduled Report Interval

The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 12 (12x30 =360 minutes). Value = 0: Disable Battery level scheduled report.
Size: 1 Byte, Default Value: 12

Setting Description
0 0

Parameter 6: The 12V DC Power Output Options

This parameter is used to enable/disable the 12V CD power output at the power output terminal. Range: 0~1. Default: 0. Value = 0: The power output is disabled; Value = 1: The power output is enabled.
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Technical Data

Hardware Platform ZGM130S037HGN2 / ZGM130S037HGN1
Device Type Lock DT
Network Operation Listening Sleeping Slave
Firmware Version HW: 01 FW: 01.03
Z-Wave Version 7.15.4
Certification ID ZC14-22020058
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Lock DT