This is a
If not included to a Z-Wave network, the device will attempt to be added to the network at power-up following an LED start-up sequence.The controller must be put into include mode before plugging in the device.During normal operation, after putting the controller into include mode, a single press of the round Z-Wave button will add the device to the Z-Wave network.
The VeriLock Translator is an indoor device that allows users to monitor the status of over 100 VeriLock sensors by Nexia Home Intelligence using standard Z-Wave interfaces.These sensors are added to the VeriLock Translator as Multi Channel End Points.Because the number of sensors in a home is dynamic, the number of End Points on the device is also dynamic. Unlike the VeriLock Translator, the sensors are NEVER represented as nodes on the Z-Wave network and cannot communicate over the Z-Wave network.Their status, however, is reported by the VeriLock Translator over the Z-Wave network via the Multi Channel Command Class.The VeriLock Translator is added to the Z-Wave network as a Repeater and implements the Routing Slave library.The VeriLock Translator is a Z-Wave Plus certified device.
Reset to factory default | The device is factory reset by pressing and holding both the round (Z-Wave) and square (Multi-Purpose) buttons simultaneously for 15 seconds.Please use this procedure only in emergencies such as when the network primary controller is missing or otherwise inoperable.This should always be used as a last resort. |
Inclusion | If not included to a Z-Wave network, the device will attempt to be added to the network at power-up following an LED start-up sequence.The controller must be put into include mode before plugging in the device.During normal operation, after putting the controller into include mode, a single press of the round Z-Wave button will add the device to the Z-Wave network. |
Exclusion | After putting the controller in exclude mode, a single press of the round Z-Wave button will remove the device from the Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Adjust the buzzer volume Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | 100 is max volume. 0 is off. |
Start, stop, or get the results of Discovery Mode. Retrieve the configuration parameter to obtain the results of discovery mode:0=Not Enabled, 1=Enabled, 2=Timed Out, 3=Failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Enable |
0 | Disable |
Turn Sleep Mode ON or OFF. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF |
1 | ON |
Hardware Platform | ZM5202 |
Device Type | Repeater |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-14120001 |
Z-Wave Product Id | 0x0178.0x5A44.0x414E |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |