This is a
A This is a Z-Wave actuator. Inclusion and Exclusion are confirmed by a single click on the button.
If the Aeon Labs Inline Smart Energy Switch is not included into any Z-Wave network,
the LED will be blinking continually.The device supports secure communication.
The Aeon Labs Inline Smart Energy Switch is a Z-Wave light switch specifically used to enable Z- Wave commands and control (on/off) a device that is connected to a standard Schuko Wall Outlet.
It can also report immediate wattage consumption or kWh energy usage over a period of time. The wireless module is powered from the mains supplys. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status. This device support secure communication when included by a controller that also supports secure communication. The device will then send all commands as secure commands unless the receiving device can not accept them. Then the command is send the normal way automatically.
This device can be plugged between every Standard-Schuko wall outlet and the electrical appliance with maximum load of 3500W. To switch the plugged device on or off simply push the local button once or use a Z-Wave Controller. The status is shown by the status LED at the device.
The switch is operated by the local switch/button or wireless via Z-Wave. The click on the switch sets the switch on or off.
The Aeon Labs Inline Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z-Wave gateway or controller when requested. If this function is supported by the gateway/controller, the energy consumption will be displayed in the user interface of the gateway/controller. Please consult the operation manual for these gateways/controllers for specific instructions.
Reset to factory default | XXXResetDescription |
Inclusion | To include this device with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If this device was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed. |
Exclusion | To include this device with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If this device was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed. |
NIF |
A single click at the Inclusion/Exclusion switch sends a Node Information Frame. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 |
2 | 5 | Group 2 |
3 | 5 | Group 3 |
This is a double byte value. The LSB defines the total time the device needs to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled). Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Active Overload Protection |
01 | Deactivate Overload Protection |
Configure the output load status after reu2010power on. Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | last status |
01 | always on |
02 | always off |
Defines the automated status notification of an associated device when status changes (0=nothing, 1=hail CC, 2=basic CC report). Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | nothing |
01 | hail |
02 | basic CC report |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | The LED will follow the status (on/off) of its load. |
01 | When the state of Switchu2019s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Enabled parameter 91/92 |
01 | Disabled parameter 91/92 |
The value represents the minimum change in wattage for a report to be sent . Size: 2 Byte, Default Value: 0019
Setting | Description |
---|
The value represents the minimum change in wattage Percent for a report to be sent. (Valid values 0u2010100) Size: 1 Byte, Default Value: 05
Setting | Description |
---|
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | set to default |
01 | nothing |
Defines the type of report sent for the Reporting Group 1. Size: 4 Byte, Default Value: 00000008
Setting | Description |
---|---|
00000002 | Multisensor Report |
00000004 | Meter Report for Watt |
00000008 | Meter Report for kWh |
Defines the type of report sent for the Reporting Group 2. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
00000002 | Multisensor-Report |
00000004 | Meter Report for Watt |
00000008 | Meter Report for kWh |
Defines the type of report sent for the Reporting Group 3. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
00000002 | Multisensor-Report |
00000004 | Meter Report for Watt |
00000008 | Meter Report for kWh |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Set to default |
01 | nothing |
Defines the time interval when the defined report of Reporting Group 1 is sent out. Size: 4 Byte, Default Value: 000002d0
Setting | Description |
---|
Defines the time interval when the defined report of Reporting Group 2 is sent out. Size: 4 Byte, Default Value: 000002d0
Setting | Description |
---|
Defines the time interval when the defined report of Reporting Group 3 is sent out. Size: 4 Byte, Default Value: 0000ffff
Setting | Description |
---|
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Aeon Labs Standard |
01 | AT&T |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Deactivate configurationlock |
01 | Activate configurationlock |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 02.19 |
Z-Wave Version | 03.53 |
Z-Wave Product Id | 0086.0003.004b |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |