Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeon Labs Smart Switch Gen5 is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 16A current of resistive loads. It also acts as a repeater that forwards Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.
By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.
Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the switch is turned on or off using the action button, the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the product receives a controlling Basic Set CC/Switch Binary Set CC/ Scene Activation Set CC, which if cause the productu2019s load state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC /Scene Activation Set CC to nodes in group 2.

Configuration Parameters

Parameter 101: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 1. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 4

Setting Description
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh
1 Report Instantaneous Voltage

Parameter 102: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 2. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 8

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 103: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 3. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 0

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 111: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second).
Size: 4 Byte, Default Value: 300

Setting Description
0 - 268435456 Interval Seconds

Parameter 112: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second).
Size: 4 Byte, Default Value: 600

Setting Description
0 - 268435456 Interval Seconds

Parameter 113: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second).
Size: 4 Byte, Default Value: 600

Setting Description
0 - 268435456 Interval Seconds

Parameter 2: Make Smart Switch blink

This parameter is used for customer to control the productu2019s load (e. g incandescent light) to blink with a certain time when you set this parameter and send this command to the load.
Size: 2 Byte, Default Value: 3850

Setting Description
0 - 255 Specify the time that Smart Switch should blink, in seconds.
256 - 32767 Specifies the cycle of on/off, the unit of it is 0.1 second.

Parameter 200: Partner ID

This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others).
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters. (0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 254: Device Tag

This parameter is used to save the device tag, which will be written/ assigned in factory/ manufacturer.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32767 Device Tag

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
1 Resets all configuration parameters to default setting.

Parameter 3: Current Overload Protection

This parameter is used for the overload protection, which means the load will be disconnected after 2 minutes when the current more than 16.2A.
Size: 1 Byte, Default Value: 0

Setting Description
0 Overload Protection Disabled
1 Overload Protection is Enabled

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices.

This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5u2019s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC).
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing (Disabled)
1 Send HAIL Command
2 Send BASIC Report Command

Parameter 90: Enable/Disable the function of parameter 91 and 92.

This parameter is used to Enable/Disable the function of parameter 91 and 92 (1=Enabled, 0=Disabled).
Size: 1 Byte, Default Value: 1

Setting Description
0 Configuration Parameters 91 and 92 are Disabled
1 Configuration Parameters 91 and 92 are Enabled

Parameter 91: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 25

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Technical Data

Dimensions 78x54x75 mm
Weight 91 gr
Hardware Platform ZM5202
EAN 1220000012905
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.00
Certification ID ZC10-14090009
Z-Wave Product Id 0x0086.0x0003.0x004B
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch