This is a
- Push the button on backside
Installed in an electricity box, the energy meter will monitor the total consumption of electricity used by an entire building. And its intelligent clamps will report that energy use back to your Z-Wave gateway or controller, in watts or kilowatt-hours, and in real time. So you can see how much electricity you really use and when you use it.
Unless otherwise stated, the circuit box?s main breaker should be turned off to perform these installation steps.
It is now time to place the main body of the Home Energy Meter. Inside the meter is a radio antenna used for communications, and this must be taken into consideration when selecting a location for the meter.
If the circuit boxes is made of metal the radio signal strength may be reduced. In this situation it is recommended that the main body of the meter be affixed outside the circuit box. This will improve the radio signal strength. The Home Energy Meter has been weatherized to the international IP43 standard so that it is resistant to rain and snow when placed vertically with the wires protruding from the bottom of the unit.
To place the Home Energy Meter:
Reset to factory default | - Press and hold the button on the backside for 10 seconds |
Inclusion | - Push the button on backside |
Exclusion | - Push the button three times on backside |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Send configured Value to devices |
For parameters of 101, power, energy detection mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report power, energy absolute value |
1 | report positive/negative power, report the algebraic sum energy |
2 | report positive/negative power, only report energy positive part (consuming electricity) |
3 | report positive/negative power, only report energy negative part (generating electricity) |
Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Threshold change in wattage to induce a automatic report (Whole HEM). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 60000 | Watt |
Threshold change in wattage to induce a automatic report Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 60000 | Watt |
Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid value |
Percentage change in wattage to induce a automatic report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid value |
Enable /disable reporting CRC-16 Encapsulation Command Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
1 | enable |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | reset parameter 101 |
Example: 1 + 1024 = Value 1025
If you want to report everthing, you would add the whole table together and set in to 101.
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Report Total HEM - KWH |
2 | Report Total HEM - Watt |
4 | Report Total HEM - Voltage |
8 | Report Total HEM - Current |
256 | Report Watt for Clamp 1 |
2048 | Report KWH for Clamp 1 |
65536 | Report Voltage (V) for Clamp 1 |
524288 | Report Current (A) for Clamp 1 |
Set the report intervall for Group 1 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 2097152 | seconds |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 | others |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
1 | enable |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset to factory default setting |
1431655765 | Reset to factory default setting and removed from the zwave network |
Dimensions | 161x147x40 mm |
Weight | 370 gr |
Hardware Platform | ZM5202 |
EAN | 1220000015777 |
IP Class | IP 44 |
Voltage | 230V |
Load | 200 A |
Device Type | Smart Meter |
Firmware Version | 1.21 |
Z-Wave Version | 03.5c |
Certification ID | ZC10-15120010 |
Z-Wave Product Id | 0x0086.0x0002.0x005f |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |