This is a
Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals, you just need to connect the matched external sensor on it, such as the water level sensor, dry contact switch, dry contact relay and so on. In other words, it can be used if the external sensor is a dry contact.
It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating†that allows you wirelessly update its firmware if needs.
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
Reset to factory default | Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find in back of the product. |
NIF | XXXNIF |
Wakeup | Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has max 5 nodes to associate. The Basic Set CC or Sensor Binary report CC will be sent to the associated nodes in Group 1. |
This parameter is used to set the Sensor binary report value when the Sensor is triggered On or Off. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When the Sensor is triggered On, Sensor Binary Report=0xFF. When the Sensor is triggered Off, Sensor Binary Report=0x00. |
1 | When the Sensor is triggered On, Sensor Binary Report=0x00. When the Sensor is triggered Off, Sensor Binary Report=0xFF. |
This parameter is used to set the interval time of battery report. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The periodic battery report is disabled. |
1 - 2147483647 | the range of interval time is 1 seconds to 2147483647 seconds. |
This parameter is used to set which command will be sent to the associated nodes when the Sensor is triggered On/Off. Size: 4 Byte, Default Value: 256
Setting | Description |
---|---|
16 | Send Sensor Binary Report to associated nodes when the Sensor is triggered On/Off. |
256 | Send Basic Set to associated nodes when the Sensor is triggered On/Off. |
272 | Send the Sensor Binary Report and Basic Set to associated nodes when the Sensor is triggered On/Off. |
This parameter is used to set a Notification type for Dry Contact Sensor. Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
1 | The Smoke Alarm notification type is selected for the Sensor. |
2 | The CO Alarm notification type is selected for the Sensor. |
3 | The CO2 Alarm notification type is selected for the Sensor. |
4 | The Heat Alarm notification type is selected for the Sensor. |
5 | The Water Alarm notification type is selected for the Sensor. |
6 | The Access Control notification type is selected for the Sensor. |
7 | The Home Security notification type is selected for the Sensor. |
8 | The Power Management notification type is selected for the Sensor. |
9 | The System notification type is selected for the Sensor. |
10 | The Emergency Alarm notification type is selected for the Sensor. |
11 | The Clock notification type is selected for the Sensor. |
This parameter is used to enable/disable wake-up 10 minutes when re-power on the Sensor. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable. |
1 | Enable. |
This parameter is used to reset the Sensor. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset to factory default settings. |
1431655765 | Reset to factory default settings and removed from the Z-Wave network. |
This parameter is used to set the Basic Set value when the Sensor is triggered On/Off. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | When the Sensor is triggered On, Basic Set=0x00. When the Sensor is triggered Off, Basic Set=0xFF. |
0 | When the Sensor is triggered On, Basic Set=0xFF. When the Sensor is triggered Off, Basic Set=0x00. |
This parameter is used to set the low battery value. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | The range of low battery value is 10% to 50% |
Dimensions | 0.0000000x0.0000000x0.0000000 mm |
Weight | 19 gr |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15090010 |
Z-Wave Product Id | 0x0086.0x0102.0x0061 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |