Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals, you just need to connect the matched external sensor on it, such as the water level sensor, dry contact switch, dry contact relay and so on. In other words, it can be used if the external sensor is a dry contact.
It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs.
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Reset to factory default Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find in back of the product.
NIF XXXNIF
Wakeup Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has max 5 nodes to associate. The Basic Set CC or Sensor Binary report CC will be sent to the associated nodes in Group 1.

Configuration Parameters

Parameter 1: Which value of the Sensor Binary Report will be sent when the Sensor is triggered On or Off.

This parameter is used to set the Sensor binary report value when the Sensor is triggered On or Off.
Size: 1 Byte, Default Value: 0

Setting Description
0 When the Sensor is triggered On, Sensor Binary Report=0xFF. When the Sensor is triggered Off, Sensor Binary Report=0x00.
1 When the Sensor is triggered On, Sensor Binary Report=0x00. When the Sensor is triggered Off, Sensor Binary Report=0xFF.

Parameter 111: Set the interval time of battery report.

This parameter is used to set the interval time of battery report.
Size: 4 Byte, Default Value: 0

Setting Description
0 The periodic battery report is disabled.
1 - 2147483647 the range of interval time is 1 seconds to 2147483647 seconds.

Parameter 121: To set which command will be sent to the associated nodes when the Sensor is triggered On/Off.

This parameter is used to set which command will be sent to the associated nodes when the Sensor is triggered On/Off.
Size: 4 Byte, Default Value: 256

Setting Description
16 Send Sensor Binary Report to associated nodes when the Sensor is triggered On/Off.
256 Send Basic Set to associated nodes when the Sensor is triggered On/Off.
272 Send the Sensor Binary Report and Basic Set to associated nodes when the Sensor is triggered On/Off.

Parameter 122: Set a Notification type for Dry Contact Sensor.

This parameter is used to set a Notification type for Dry Contact Sensor.
Size: 1 Byte, Default Value: 6

Setting Description
1 The Smoke Alarm notification type is selected for the Sensor.
2 The CO Alarm notification type is selected for the Sensor.
3 The CO2 Alarm notification type is selected for the Sensor.
4 The Heat Alarm notification type is selected for the Sensor.
5 The Water Alarm notification type is selected for the Sensor.
6 The Access Control notification type is selected for the Sensor.
7 The Home Security notification type is selected for the Sensor.
8 The Power Management notification type is selected for the Sensor.
9 The System notification type is selected for the Sensor.
10 The Emergency Alarm notification type is selected for the Sensor.
11 The Clock notification type is selected for the Sensor.

Parameter 2: Enable/disable wake-up 10 minutes when re-power on the Sensor.

This parameter is used to enable/disable wake-up 10 minutes when re-power on the Sensor.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable.
1 Enable.

Parameter 255: Reset the Sensor.

This parameter is used to reset the Sensor.
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset to factory default settings.
1431655765 Reset to factory default settings and removed from the Z-Wave network.

Parameter 3: Which value of the Basic Set will be sent when the Sensor is triggered On/Off.

This parameter is used to set the Basic Set value when the Sensor is triggered On/Off.
Size: 1 Byte, Default Value: 0

Setting Description
1 When the Sensor is triggered On, Basic Set=0x00. When the Sensor is triggered Off, Basic Set=0xFF.
0 When the Sensor is triggered On, Basic Set=0xFF. When the Sensor is triggered Off, Basic Set=0x00.

Parameter 39: Set the low battery value.

This parameter is used to set the low battery value.
Size: 1 Byte, Default Value: 10

Setting Description
10 - 50 The range of low battery value is 10% to 50%

Technical Data

Dimensions 0.0000000x0.0000000x0.0000000 mm
Weight 19 gr
Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.06
Certification ID ZC10-15090010
Z-Wave Product Id 0x0086.0x0102.0x0061
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor