Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusion mode, press the external switch of LED Bulb to turn it off and then press the external switch again to turn it on.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeotec LED Bulb is a low-cost Z-Wave LED module which allows control (on/off/dim) with the use of Z-Wave.
Itâ??s a bulb has a Smart RGB LED, which can be used to add colour to your home. The bulb has 5 main colour channels available for you to adjust: Red, Green, Blue, Warm White and Cold White. You can configure its colour according to your favour.
The LED Bulb is also a security Z-wave device and supports the Over The Air (OTA) feature for the productâ??s firmware upgrade.

Reset to factory default Turn the controller of Z-Wave network into exclusion mode, press the external switch of LED Bulb to turn off and then press the external switch again to turn on it, repeat the operation 3 times. After the LED Bulb is excluded from network, it will be reset to factory default state. Use this procedure only in the event that your primary network controller is missing or inoperable.
Inclusion 1. Install the device according to the instructions.
2. Switch ON the bulb.
3. Swich OFF and On the bulb 3 times.
Exclusion
1. Turn on the Bulb. 
2. Switch the Bulb off and on 3 times in a row.
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Bulb is turned on or off using the external switch, the Bulb will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the product receives a controlling Basic Set CC/Switch Binary Set CC/Switch Multilevel Start Level Change CC, Switch Multilevel Stop Level Change CC, Switch Multilevel Set CC, Scene Activation Set CC, which if cause the productu2019s state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC to nodes in group 2.

Configuration Parameters

Parameter 34: Enable/disable the function of using external switch to turn on/off the bulb.

This parameter is used to enable/disable the function of using external switch to turn on/off the bulb.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 35: Enable/disable the function of using external switch to turn on/off the bulbs color.

This parameter is used to enable/disable the function of using external switch to turn on/off the bulb‘s color.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices.

This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of bulb is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC).
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing (Disabled)
1 Send HAIL Command
2 Send BASIC Report Command

Parameter 200: Partner ID

This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others).
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1 Reset all configuration parameters to default setting.
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.

Technical Data

Dimensions 0.0600000x0.1060000x0.0500000 mm
Weight 243 gr
Hardware Platform ZM5101
EAN 1220000012974
IP Class IP 20
Voltage 230V
Load 9W
Device Type Light Dimmer Switch
Network Operation Always On Slave
Z-Wave Version 6.51.06
Certification ID ZC10-16065126
Z-Wave Product Id 0x0086.0x0003.0x0062
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeLight Dimmer Switch