Quickstart

This is a secure Dimmer for XXXQFrequencyName. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product"s housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Smart Dimmer 6 is an intelligent socket, which you can switch by remote, wall switch, smartphone or automation. Thanks to Z-Wave the Smart Dimmer 6 offers you much more than a conventional socket. The Smart Dimmer 6 is equipped with a premium energy monitoring, that provides the Z-Wave controller with real-time consumption data of the associated device. All data can be stored and redisplayed afterwards as progression charts. In addition, the coloured LED ring of the Smart Dimmer 6 displays the power requirements of the device in a visual way. The LED ring can be configured as follows:

  • Deactivated: The LED ring is permanently disabled
  • 2-coloured: Blue, if the monitored device is on; White if it"s switched off.
  • 16 Million Colours: The colours vary from blue to yellow, green and red (where blue is the lowest and red the highest energy consumption of the monitored device).

Installation

The Smart Dimmer 6 can be placed between every normal wall socket and any electrical device with a load up to 3500W. To switch the connected device it is enough to press the action button or you can use your Z-Wave controller to send commands to your Smart Dimmer. The current status is indicated by the LED.

Product Usage

The device can be can be controlled either by pressing the action button or sending commands from the Z-Wave Controller. A single press on the button switches between active and inactive.

The Smart Energy Switch monitors the current power and energy consumption in kWh and can send this information to your Z-Wave Controller. How or if the data is displayed depends on your Z-Wave Controller. For more information please look up the Controller"s manual.

Reset to factory default 1. Make sure the Smart Dimmer has been connected to the power supply.
2. Press and hold the Z-wave button for 20 seconds. 
3. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20seconds, the green LED will be on for 2 seconds and then remain colorful gradient status, it indicates reset success, otherwise please repeat step 2..
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product"s housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product"s housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Dimmer is turned on or off using the action button, the Dimmer will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the product receives a controlling Basic Set CC/Switch Multilevel Start Level Change/ Switch Multilevel Stop Level Change/ Switch Multilevel Set command, which if cause the products load state to be changed, which will lead to send the Basic Set CC//Switch Multilevel Start Level Change/ Switch Multilevel Stop Level Change/ Switch Multilevel Set command to nodes in group 2.

Configuration Parameters

Parameter 3: Current Overload Protection

This parameter is used for the overload protection, which means the load will be disconnected after 2 minutes when the current more than 14A.
Size: 1 Byte, Default Value: 0

Setting Description
0 Overload Protection Disabled
1 Overload Protection is Enabled

Parameter 20: Configure the output load status after re-power on

Configure the output load status after re-power on the Smart Switch.
Size: 1 Byte, Default Value: 0

Setting Description
0 The output load status will be the same as the previous state before a power outage.
1 The output load status will be ON state after re-power on.
2 The output load status will be OFF state after re-power on.

Parameter 33: Change the color value of RGB LED for testing

This parameter is only used for customer checking/testing the products RGB color via changing the RGB values.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 255 Reserved
255 - 65535 Range of red color value.
65536 - 16777215 Range of green color value.
16777215 - 2147483647 Range of blue color value.

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices.

This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5 load is changed. 
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing (Disabled)
1 Send HAIL Command
2 Send BASIC Report Command

Parameter 81: Configure the state of LED

This parameter is used to configure the LED state when the Smart Switch is in Energy mode/Momentary indicate mode/Night light mode.
Size: 1 Byte, Default Value: 0

Setting Description
0 The state of LED will follow with the output load state(Energy mode)
1 The state of LED will follow with the output load state, but will turn off after 5 seconds if there is no any switch action.(Momentary indicate mode)
2 The state of LED will the same with Night light mode state configured by parameter 83.

Parameter 83: Configure the LED indication status when it is in Night light mode

This parameter is used to configure the LED indication status when the current mode is Night light mode.
Size: 4 Byte, Default Value: 14524637

Setting Description
0 - 255 Set the indication value of red Led.
256 - 65535 Set the indication value of green Led.
65536 - 16777215 Set the indication value of blue Led.

Parameter 84: Configure the brightness level for the LED indication

This parameter is used to configure the brightness level for the LED indication.Brightness level range is 0 to 100%.
Size: 1 Byte, Default Value: 50

Setting Description
0 - 100 Brightness level range is 0 to 100%.

Parameter 90: Enable/Disable the function of parameter 91 and 92.

This parameter is used to Enable/Disable the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 1

Setting Description
0 Configuration Parameters 91 and 92 are Disabled
1 Configuration Parameters 91 and 92 are Enabled

Parameter 91: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 25

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Parameter 100: Reset Parameter 101 - 103


Size: 1 Byte, Default Value: 0

Setting Description
1 Reset Parameter 101-103

Parameter 101: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 4

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 102: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 8

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 103: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 0

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 110: Reset Parameter 111-113


Size: 1 Byte, Default Value: 0

Setting Description
1 Reset Parameter 111-113

Parameter 111: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 1. 
Size: 4 Byte, Default Value: 600

Setting Description
0 - 268435456 Interval Seconds

Parameter 112: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 2. 
Size: 4 Byte, Default Value: 600

Setting Description
0 - 268435456 Interval Seconds

Parameter 113: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 3.
Size: 4 Byte, Default Value: 600

Setting Description
0 - 268435456 Interval Seconds

Parameter 200: Partner ID

This parameter is used to configure the partner ID. 
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 254: Device Tag

This parameter is used to save the device tag, which will be written/ assigned in factory/ manufacturer.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32767 Device Tag

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1 Resets all configuration parameters to default setting.
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.

Technical Data

Dimensions 0.0580000x0.0580000x0.0700000 mm
Weight 118 gr
Hardware Platform ZM5202
IP Class IP 20
Voltage 230 V
Load 2,5A
Device Type Dimmer
Firmware Version 01.02
Z-Wave Version 04.05
Z-Wave Product Id 0x0086.0x0003.0x0063
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeDimmer