This is a
Aeotec Nano Dimmer is a Z-Wave Smart Dimmer specifically used to enable Z-Wave command and control (on/off/dim) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Nano Dimmer. The Nano Dimmer is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade.
1. Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation which will cause damage to the Nano Dimmer
2. Preparing connection wires 14 AWG or 12 AWG power wires for Input/Output. 18 AWG copper wires for external manual switch. Use the wire stripper cut the metallic part of the connection wire and make sure the length of the metallic part is about 5mm.
Note: All connection wires need to be flexible cable
Reset to factory default | Press and hold the Action button that you can find on the product"s housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. |
Inclusion | 1. Install the device according to the instructions. 2. Press the button 2 times within 1 second on the Nano Dimmer. |
Exclusion | 1. Press the button once on the Nano Dimmer. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.When the load state of Nano Dimmer (on/off/dim the load ) is changed, the Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all to the associated nodes in Group 2 when the Nano Dimmer receives the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all commands from main controller. |
3 | 5 | Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated |
4 | 5 | Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated |
Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100°C. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Configure the output status after re-power on it. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last status |
1 | Always on |
2 | Always off |
To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Multilevel Switch report |
4 | Send Hail CC when using the manual switch to change the load state. |
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
Set the ON time of output load. Size: 4 Byte, Default Value: 1573017
Setting | Description |
---|---|
0 - 99 | The brightness level |
256 - 316 | The minute value of ON time |
65536 - 65560 | The hour value of ON time |
16777215 - 16777222 | The day value (Mon to Sun) |
Set the ON time of output load. Size: 4 Byte, Default Value: 2293760
Setting | Description |
---|---|
0 - 99 | The brightness level |
256 - 316 | The minute value of ON time |
65536 - 65560 | The hour value of ON time |
16777215 - 16777222 | The day value (Mon to Sun) |
Enables/disables the function of parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Threshold change in wattage (in terms of wattage) to induce an automatic report. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 60000 | The thershold value range is 0 to 60000 |
Threshold change in wattage (in terms of percentage) to induce an automatic report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The thershold value range is 0 to 100 |
Set parameter 101-103 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 101-103 |
To set which reports need to be sent in Report group 1. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 3. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
Set parameter 111-113 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 111-113 |
Set the interval of automatic report for Report group 1. Size: 4 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 2. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 3. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Configure the external switch mode for S1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
Configure the external switch mode for S2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
Get the state of touch panel port Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the touch panel is not connected. |
5 | the touch panel is connected. |
Set the control destination for external switch S1 Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes. |
Set the control destination for external switch S2. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes. |
3 | control the output loads of itself and other nodes |
Set the default dimming rate. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 255 | The value range is 1 to 255 seconds. |
Get the current working mode.Note: This parameter is a Get-only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unknown working mode. |
1 | 2-wire mode |
2 | 3-wire mode |
Set the dimming principle. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Trailing edge mode |
1 | Leading edge mode |
To get what type of load the Dimmer is connected to.Note: This parameter is a Get-only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unknown load. |
1 | Resistive load |
2 | Capacitive load |
3 | Inductive load |
Set the min brightness level that the load can reach to. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | The level range is 0 to 99. |
Set the max brightness level that the load can reach to.Note: Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | The level range is 0 to 99. |
Set the recognition way of load Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Never recognize the load when power on |
1 | Only recognize once when first power on |
2 | Recognize the load once power on |
Lock/unlock configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Reset the Nano Dimmer to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to factory default setting |
1431655765 | Reset to factory default setting and removed from the z-wave network |
Dimensions | 0.0420000x0.0395000x0.0200000 mm |
Weight | 26.62 gr |
Hardware Platform | ZM5101 |
EAN | 1220000013971 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 276W |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17015388 |
Z-Wave Product Id | 0x0086.0x0003.0x006F |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |