Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * internal Lithium batteries. To run this device please make sure the internal battery is fully charged. Turn the primary controller into inclusion mode, short press the product?s Action Button that you can find in the back of the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window"s open/close in real time.
It?s a security Z-Wave device that supports security encryption. Also it supports the ?Over the Air Firmware Updating? that allows you wirelessly update its firmware if needs.
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Installation

Whether it?s for security or intelligence purposes, your sensor:

 

1.   Should be affixed indoors and away from sources of moisture.

2.   Placed within 30 meters of another Z-Wave device that is either a gateway or not powered by batteries.

3.   The magnet and the main sensor must be less than 1.6cm apart for the small magnet installation or 2.5cm apart for the big magnet installation. Main sensor must be affixed to the door or window and the magnet must be affixed to the frame. The magnet and the main sensor must separate when the door or window is opened.

4.   Should not be mounted on a metal frame. 


Affix your Back Mounting Plate and Magnet to a surface.

 

The Back Mounting Plate can be affixed using screws or double-sided tape and should be mounted on the apex angle of the door. The Magnet must be affixed using double-sided tape and can?t exceed the valid range, see the figure below.

 

Note:

1.   There are 2 types of Magnets (Magnet 1: 30mm×6mm×2mm, Magnet 2: 30mm×10mm×2mm) , the size of magnet 2 is a little larger than magnet 1, so the magnetism of magnet 2 is stronger than the magnet 1.

 

2.   You can choose to install each one of magnet on the door frame according to your need or the distance between the door and frame, see the figure below.




3. The Magnets should not be around children to avoid swallowing of the magnets.

 

 

When the Back Mounting Plate is affixed by the double-sided tape, wipe the two surfaces clean of any oil or dust with a damp towel. Then when the surface has completely dried, peel one side of the tape back and attach it to the corresponding section on the rear side of the Back Mounting Plate




Reset to factory default Press the Action Button once that you can find in the back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion 1. Remove the backplate
2. Press the button on the back of the sensor once.
Exclusion 1. Remove the backplate
2. Press the button on the back of the sensor once.
NIF XXXNIF
Wakeup Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. The sensor binary report, basic set or notification report command can be sent in this group when the Sensor is triggered.

Configuration Parameters

Parameter 1: Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed.

To set which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1

Setting Description
0 Sensor Binary Report/Basic Set =0xFF when the door is opened, Sensor Binary Report/Basic Set= 0x00 when the door is closed.
1 Sensor Binary Report/Basic Set= 0x00 when the door is opened, Sensor Binary Report/Basic Set=0xFF when the door is closed.

Parameter 39: Set the low battery value.

Set the low battery value.(10% to 50%).
Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 The range of low battery value can be set to 10% to 50%.

Parameter 101: Enable/disable the function of parameter 111

Enable/disable the function of parameter 111.Note: this parameter cannot disable the low battery checking of the Sensor itself.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable.
1 Enable.

Parameter 111: Set the interval time of low battery checking.

Set the interval time of low battery checking.Note:1, if the value is less than 10, the time unit is second.If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes.2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF.
Size: 4 Byte, Default Value: 86640

Setting Description
0 - 2147483647 The range of interval can be set to 0 to 2147483647.

Parameter 121: To configure which sensor report will be sent when the door is opened/closed.

To configure which sensor report will be sent when the door is opened/closed.
Size: 1 Byte, Default Value: 1

Setting Description
1 Basic Set CC is selected.
2 Sensor Binary Report CC is selected.
3 Basic Set CC and Sensor Binary Report CC are selected.

Parameter 252: Lock/unlock all configuration parameters.

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock.
1 Lock.

Parameter 252: Reset to factory defaults.


Size: 4 Byte, Default Value: 0

Setting Description
1 Reset to factory default setting
1431655765 Reset to factory default setting and removed from the z-wave network

Technical Data

Dimensions 100x72x72x10 mm
Weight 45 gr
Hardware Platform ZM5101
EAN 1220000013162
Battery Type 1 * internal Lithium
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.06
Certification ID ZC10-16010008
Z-Wave Product Id 0x0086.0x0002.0x0070
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor