This is a
1. Install the device according to the instructions.
2. Press the button 2 times quickly on the Nano Switch.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Set Parameter 255
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
Notes for the wire connection ports:
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.When the load state of Nano Switch (on/off) is changed, the Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. |
3 | 5 | Send Basic Set (configured by parameter 82) to the associated nodes in Group 3 when the external switch S1 is operated |
4 | 5 | Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external switch S2 is operated |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Over current protection. Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100°C. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Configure the output status after re-power on it. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last status |
1 | Always on |
2 | Always off |
To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Multilevel Switch report |
4 | Send Hail CC when using the manual switch to change the load state. |
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
Configure the state of LED when it is in 3 modes Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED will follow the status (on/off) of its load (Energy mode). |
256 - 316 | The hour value of ON time |
2 | Night light mode. |
Set the ON/OFF time of the LED when it is in Night light mode. Size: 4 Byte, Default Value: 524306
Setting | Description |
---|---|
0 - 60 | The minute time of OFF |
256 - 316 | The hour time of OFF |
65536 - 65596 | The minute time of ON |
16777216 - 16777276 | The hour time of ON |
Set appointment 1 Size: 4 Byte, Default Value: 2293760
Setting | Description |
---|---|
0 - 60 | The minute value of ON time |
256 - 316 | The minute value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
16777216 | Enable the setting. |
Set appointment 2 Size: 4 Byte, Default Value: 2293760
Setting | Description |
---|---|
0 - 60 | The minute value of ON time |
256 - 316 | The hour value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
16777216 | Enable the setting. |
Enables/disables the function of parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Threshold change in wattage (in terms of wattage) to induce an automatic report. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 60000 | The thershold value range is 0 to 60000 |
Threshold change in wattage (in terms of percentage) to induce an automatic report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The thershold value range is 0 to 100 |
Set parameter 101-103 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 101-103 |
To set which reports need to be sent in Report group 1. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 3. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
Set parameter 111-113 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 111-113 |
Set the interval of automatic report for Report group 1. Size: 4 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 2. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 3. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Configure the external switch mode for S1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | Momentary push button mode |
2 | 3 way switch mode |
3 | 2-state switch mode |
Configure the external switch mode for S2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | Momentary push button mode |
2 | 3 way switch mode |
3 | 2-state switch mode |
Set the control destination of the external switch. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes. |
Lock/unlock configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Reset the Nano Dimmer to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to factory default setting |
1431655765 | Reset to factory default setting and removed from the z-wave network |
Dimensions | 0.0425000x0.0400000x0.0200000 mm |
Weight | 28.5 gr |
Hardware Platform | ZM5202 |
EAN | 1220000015333 |
IP Class | IP 20 |
Voltage | 24V DC/ 230V AC |
Load | 10 A |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.00 |
Z-Wave Version | 04.22 |
Certification ID | ZC10-17035496 |
Z-Wave Product Id | 0x0086.0x0003.0x0074 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |