This is a
Aeon Labs Door/ Window Sensor Gen5 is a smart Z-Wave sensor that can detect the status of door/windows open/close in real time.
Its a security Z-Wave device that supports security encryption. Also it supports over the Air Firmware Updating, that allows you wirelessly update its firmware if needs.
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
img/AEO/AEOEZW120/Manual_Sketches_3.png
Reset to factory default | Press the Action Button once that you can find in back of the product for 20 seconds and then release. |
Inclusion | 1. Open the housing. 2. Remove the battery protection. 3. Press the button on the device once. |
Exclusion | 1. Open the housing . 2. Press the button in the device once. |
NIF | Press and hold the Action Button on the back of the Sensor unit for 3 seconds |
Wakeup | Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
Which value of the Sensor Binary Report will be sent when the door is open/close. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Close = Sensor Binary Report 255 (0xFF) Open = 0 (0x00) |
1 | Close = Sensor Binary Report 0 (0x00) Open = 255 (0xFF) |
Enable7disable wakeup 10 minutes when repower on the sensor Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disabel |
1 | enable |
Which value of the Basic Set will be sent when the door is open/close. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Close = Sensor Binary Report 255 (0xFF) Open = 0 (0x00) |
1 | Close = Sensor Binary Report 0 (0x00) Open = 255 (0xFF) |
Set the low battery value Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | in % |
Note: 1, if the value is less than 10, the time unit is second. If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes. 2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable the battery report for an interval time |
1 - 2147483647 | The interval time of battery report. |
To configure which sensor report will be sent when the Sensor is triggered On/Off. Size: 4 Byte, Default Value: 256
Setting | Description |
---|---|
16 | Sensor Binary |
256 | Basic Set |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset Parameters |
1431655765 | Facory Reset |
Dimensions | 39x79x22 mm |
Weight | 51 gr |
Hardware Platform | ZM5101 |
EAN | 1220000013360 |
IP Class | IP 20 |
Battery Type | 2 * AAA LR3 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 01.05 |
Z-Wave Version | 04.05 |
Certification ID | ZC10-16010006 |
Z-Wave Product Id | 0x0086.0x0002.0x0078 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |