This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusion mode, short press the product‘s Action button that you can find on the product‘s housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeotec Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. In the event of power failure, non-volatile memory retains all programmed information relating to the unit‘s operating status. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Installation



Notes for the wire connection ports:
N ? Power input for neutral
L ? Power input for live
IN ? Input for load power supply
OUT1 ? Output for load 1
OUT2 ? Output for load 2
S1 ? External switch control for load 1
S2 ? External switch control for load 2

Product Usage





Click one time 1
Send out a Node info without Security CC in command class list 

Quick press 2 times Send out a Node info that contains Security CC in the command 

Quick press 4 times Activate the automatic identification mode for external switch S1. The blue LED will fast blink to indicate the Nano Switch is in this mode.

Quick press 6 times Activate the automatic identification mode for external switch S1. The green LED will fast blink to indicate the Nano Switch is in this mode.

Reset to factory default Press and hold the Action button that you can find on the product‘s housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion 1. Install the device according to the instructions.
2. Press the button 2 times quickly on the Dual Nano Switch.
Exclusion 1. Press the button once on the Dual Nano Switch.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.
2 5 Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2)
3 5 Send Basic Set (configured by parameter81 ) to the associated nodes in Group 3 when the external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 120 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch.
4 5 Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter 121 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch.

Configuration Parameters

Parameter 4: Overheat protection

Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 20: Configure the output status after re-power on it.

Configure the output status after re-power on it.
Size: 1 Byte, Default Value: 0

Setting Description
0 Last status
1 Always on
2 Always off

Parameter 80: To set which notification would be sent to the associated devices (Group 1)

To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed.
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing
1 Send Hail CC
2 Send Basic CC report
3 Send Hail CC when using the manual switch to change the load state.

Parameter 81: To set which notification would be sent to the associated nodes in association group 3

To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads.
Size: 1 Byte, Default Value: 1

Setting Description
0 Send Nothing
1 Send Basic Set CC

Parameter 82: To set which notification would be sent to the associated nodes in association group 4

To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads.
Size: 1 Byte, Default Value: 1

Setting Description
0 Send Nothing
1 Send Basic Set CC

Parameter 83: Configure the state of LED when it is in 3 modes

Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode)
Size: 1 Byte, Default Value: 0

Setting Description
0 Energy mode. The LED will follow the status (on/off).
1 Momentary indicate mode. When the state of Switchu2019s load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
2 Night light mode. The LED will remain ON state.

Parameter 84: Set the ON/OFF time of the LED when it is in Night light mode.

Set the ON/OFF time of the LED when it is in Night light mode.
Size: 1 Byte, Default Value: 301991936

Setting Description
0 - 60 The minute time of OFF
256 - 316 The hour time of OFF
65536 - 65596 The minute time of ON
16777216 - 16777276 The hour time of ON

Parameter 86: Set appointment 1

Set the ON time of output load.
Size: 4 Byte, Default Value: 8327680

Setting Description
0 - 60 The minute value of ON time
256 - 316 The hour value of ON time
65536 - 65543 The day value (Mon to Sun)
16777215 Disable the setting.
16777216 Enable the setting.

Parameter 87: Set appointment 2

Set the OFF time of output load.
Size: 4 Byte, Default Value: 8327680

Setting Description
0 - 60 The minute value of ON time
256 - 316 The hour value of ON time
65536 - 65543 The day value (Mon to Sun)
16777215 Disable the setting.
16777216 Enable the setting.

Parameter 120: Configure the external switch mode for S1.

Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enter automatic identification mode
1 2-state switch mode
2 3 way switch mode
3 Momentary push button mode

Parameter 121: Configure the external switch mode for S2.

Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enter automatic identification mode
1 2-state switch mode
2 3 way switch mode
3 Momentary push button mode

Parameter 122: Set the control destination for external switch

Set the control destination for external switch
Size: 1 Byte, Default Value: 3

Setting Description
1 control the output loads of itself.
2 control the other nodes
3 control the output loads of itself and other nodes.

Parameter 252: Lock/unlock configuration parameters

Lock/unlock configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 255: Reset the Dual Nano Switch

Reset the Dual Nano Switch to factory default.
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset all configuration parameters to factory default setting
1431655765 Reset to factory default setting and removed from the z-wave network

Technical Data

Dimensions 0.0445000x0.0400000x0.0200000 mm
Weight 33 gr
Hardware Platform ZM5101
EAN 1220000015135
IP Class IP 20
Voltage 230 V
Load 10 A
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.09
Certification ID ZC10-17035518
Z-Wave Product Id 0x0086.0x0003.0x008C
Z-Wave Scene Type Scene
Electric Load Type Dimmable LEDElectronic with/without DimmingFluorescent (Non-Dimming)IncandescentInductiveLEDMagnetic with/without Dimming
Switch Type Toggle
Supported Notification Types Heat Alarm
Firmware Updatable Updatable by Consumer by RF
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch