Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A single click on the button will wakeup the device. The device supports the Z-Wave Security S2 framework with unauthenticated network keys. Please follow the instructions on the central controller when including. The device also supports Smart Start. Please scan the QR code inside the battery compartment of the device and your controller will add the device automatically when powered up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Aeotec Door/Window Sensor 7 is a sensor, which detects, if your window is opened, closed or tilted. The sensor is easily retrofittable. Furthermore, the AEOTEC Door/Window Sensor 7 can include other sensors by being connected with other binary sensors like NTC contacts, micro switches or flood sensor.

Thanks to its slim design the POPP Door/Windows can be installed unflashy on every window. The sensor just has to be installed on the window casement. Additionally, there has to be a slim magnet installed closely to the sensor at the window frame. By using a patented method the sensor can reliably detect the exact position of the window.

With the potential free input the Door/Window Sensor can also include other sensors in your Z-Wave system. For that the binary sensor is connected to the potential free input of the sensor. Besides sensors there can also be connected momentary switches, which controls scenes in your gateway.

Installation

The sensor can be mounted either on the moving part or on the fixed part of a door or a window. Mounting can be accomplished either using the tape by peeling off the protection foil or using two screws with the holes inside the battery compartment. If the tilt detection on a window (only normal windows, no roof windows) shall be used the sensor device must be placed on the moving part of the window and the magnet on the window frame. The sensor comes with two types of magnets:

  • The standard magnet covered by plastic part, mountable beside the sensor. Make sure the two indicating lines on sensor enclosure and magnet are opposite to each other. The image on the right handside shows the position of magnet and sensor body.
  • A slim naked magnet to be mounted behind the sensor in case the sensor body is placed on the side of a window.
  • To use the tilting function, the opening angle of the window must be at least 5°.
For German styly windows there the window sits on top of the windo frame mounting on the side of the window is highly recommended. If no tilting detection is used, the sensor can be placed on any position of the door or the window. In case tilting detection is desired the sensor should be placed on the upper side of the window.

Product Usage

Once installed the sensor will report ‘open‘ and ‘close‘ status changes to a central Z-Wave controller using notification commands. Addtionally the sensor can directly control other device using the association group 2. Using configuration commands the source of ‘open‘ and ‘close‘ events can choosen between the internal magnet detector or external dry contact connected via the screw terminal. The device is protected by a tamper switch. 

Tilt detection

The tilt detection allows reporting the way a window is opened. This is accomplished using the command class ‘binary sensor - tilt type‘. In case the window is closed or opened without tilting the tilt sensor will report ‘Off‘. In case the window is tilted a ‘On‘ is reported. The angle of inclination of the window must be at least 5°.

Adjust the tilt sensitivity via Parmater 15. Note that the value 100 has a high sensitivity and the value 1 a very low sensitivity. The default value is 50.

Screw Terminal

The product must support interconnection of external sensors as well as actuators and dry-contacts. Product allows interconnection with external sensors/actuators via 4-pin screw terminals with the following pinout:

  • #1:       VCC (direct battery supply)
  • #2:       Analogue Input (ADC - not used at the moment)
  • #3:       Digital Input
  • #4:       Ground 
VCC + Ground terminals can be used to externally power the sensor. Digital + Ground is used to connect the external dry contact.

Link testing

When activated by configuration parameter #4 the device can perform a link test with device No.1. Double clicking the tamper will start the process. As a result the red LED will blink one time in case of success and three times in case of failure.

Scene Controller

When activated by configuration parameter #13 the device can perform as a scene controller. The external dry contact will then act as a scene controller with a total of 7 scenes that can be activated:
  • 1 - Contact Pressed 1 time
  • 2 - Contact Pressed 2 time
  • 3 - Contact Pressed 3 time
  • 4 - Contact Pressed 4 time
  • 5 - Contact Pressed 5 time
  • 6 - Contact held down
  • 7 - Contact released
The device sends the following notifications to the central controller:
  • Window Opened(0x06 - 0x16)
  • Window Closed(0x06 - 0x17)
  • Tamper Removed(0x07 - 0x03)

The device sends the following sensor binary reports to the controller:
  • Tilt(0x0B)

Reset to factory default Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks.
Inclusion 1. Open the housing.
2. Remove the battery protection.
3. Press the tamper on the side of the appliance three times quickly.
Exclusion 1. Open the housing.
2. Press the tamper on the side of the appliance three times quickly.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate Wake Up the device by removing the cover. The hit the tamper switch once.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline
2 5 Control devices when magnet or external dry contacts trips
3 5 sends our alarm message when magnet controlled or external dry sensor trips.
4 5 sends alarm messages when tamper is tripped

Technical Data

Dimensions 28x95x35 mm
Weight 13 gr
Hardware Platform ZM5101
EAN 1220000016408
IP Class IP IP 20
Voltage 3,6V
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01.00
Z-Wave Version 06.02
Certification ID ZC10-19066568
Z-Wave Product Id 0371.0002.0007
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor