This is a
Aeotec Radiator Thermostat is a Z-Wave radio standard compatible energy-saving radiator thermostat for Europe.
Mounting the Aeotec Radiator Thermostat
Buttons:
Boost-Taste Led‘s
LCD
Inserting batteries
Reset to factory default | 1. Remove batteries. 2. Press and hold boost button. 3. While still holding boost button insert batteries. 4. The LCD shows RES. Release boost button. 5. To perform the factory reset press boost button. |
Inclusion | 1. Insert the batteries 2. Press the Boost-Button once. |
Exclusion | 1. Press and hold the boost button of the Radiator Thermostat for at least 5 seconds. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Inverts the LCD orientation Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal orientation |
1 | LCD content inverted |
Configures the timeout of the LCD. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LCD always on |
5 - 30 | LCD timeout in seconds |
Enables or disables the LCD-Backlight. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Backlight disabled |
1 | Backlight enabled |
Enables or disables unsolicited battery reporting once a day. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Battery reporting disabled |
1 | Battery reporting enabled |
Reports the measured roomtemperature on change. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 50 | Reporting Delta in 1/10 Celcius |
Reports the valve percentage on change. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 100 | Reporting Delta in percent |
Configures the sensitivity of the window open detection.Sensitivity level: 1 low2 medium3 high Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Detection disabled |
1 - 3 | Sensitivity level |
Configures an offset for the measured temperature. Set the offset to -128 (0x80) if measured temperature is provided externally. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | Offset in 1/10 Celcius (0°C - 5°C) |
128 | Temperature is supplied externaly |
206 - 255 | Offset in 1/10 Celcius (-5°C - 0,1°C) |
Dimensions | 55 x 67x 67 mm |
Weight | 127 gr |
Hardware Platform | ZM5202 |
EAN | 4251295701387 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 2 * AA LR6 |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-20076945 |
Z-Wave Product Id | 0x0371.0x0002.0x0015 |
Firmware Updatable | Updatable by Consumer by RF |
Sensors | Air Temperature |
Supported Notification Types | Power ManagementSystem |
Thermostat HVAC Systems Supported | Heat Only |
Thermostat Modes | Energy Save HeatHeat |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |