This is a
Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.
By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary âlisteningâ Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.
Reset to factory default | Press and hold the Action button that you can find on the products housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | 1. Open the housing. 2. Press the button once. |
Exclusion | 1. Open the housing. 2. Press the button once. |
NIF | XXXNIF |
Wakeup | N/A |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the switch is turned on or off using the action button, the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80. |
2 | 5 | When the product receives a controlling Basic Set CC/Switch Binary Set CC/ Scene Activation Set CC, which if cause the productu2019s load state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC /Scene Activation Set CC to nodes in group 2. |
This parameter is used to configure which reports need to be sent in Report Group 1. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 4
Setting | Description |
---|---|
4 | Report Instantaneous Watts |
1 | Report Instantaneous Voltage |
8 | Report Accumulated kWh |
2 | Report Instantaneous Current (Amperes) |
This parameter is used to configure which reports need to be sent in Report Group 2. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 8
Setting | Description |
---|---|
2 | Report Instantaneous Current (Amperes) |
1 | Report Instantaneous Voltage |
4 | Report Instantaneous Watts |
8 | Report Accumulated kWh |
This parameter is used to configure which reports need to be sent in Report Group 3. The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported. See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
8 | Report Accumulated kWh |
1 | Report Instantaneous Voltage |
2 | Report Instantaneous Current (Amperes) |
4 | Report Instantaneous Watts |
This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second). Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second). Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second). Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used for indicating the state of output load after re-power on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | The load state will always off stare after re-power on. |
0 | The load state will back to the last state after power on. |
1 | The load state will always on after re-power on. |
This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 255 | Partner ID of Partner Product |
This parameter is used to enable/disable Lock all configuration parameters. (0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | All configuration parameters are configurable. |
1 | All configuration parameters are not configurable (Locked). |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
1 | Resets all configuration parameters to default setting. |
This parameter is used for the overload protection, which means the load will be disconnected after 5 seconds when the current more than 39.5A. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Overload Protection Disabled |
1 | Overload Protection is Enabled |
This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5u2019s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | Send BASIC Report Command |
0 | Send Nothing (Disabled) |
1 | Send HAIL Command |
This parameter is used to Enable/Disable the function of parameter 91 and 92 (1=Enabled, 0=Disabled). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Configuration Parameters 91 and 92 are Disabled |
1 | Configuration Parameters 91 and 92 are Enabled |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
Dimensions | 117x150x40 mm |
Weight | 346 gr |
Hardware Platform | ZM5202 |
EAN | 1220000012547 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.00 |
Certification ID | ZC10-14090016 |
Z-Wave Product Id | 0x0086.0x0003.0x004E |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |