Use Network Management Buttons to include and exclude devices to the remote controls network and use the LEARN button to include the minimote into a different network. Pushing the LEARN button for 5 sec will wake up the device.
The Aeon Labs mini remote control can control a variety of Z-Wave compatible devices such as switches, dimmers, window blinds and motion sensors. The device can include and exclude devices, group them and set and release associations. The mini remote only offers four control buttons for scene selection. Behind a slider there are four more buttons for Z-Wave network control. A non-replaceable but rechargeable battery powers the remote control. Recharging is done on a conventional USB bus using the charging cable provided. The product is in the color white.
The device is ready for use. In case there are no LED signals when hitting the buttons the device needs to be recharged using the USB cable provided.
The Minimote has 4 scene control buttons. A scene defines a certain switching state for a number of devices connected to this scene. A single click on the scene button will then turn all these devices into the desired switching state. Below the cover there are 4 dedicated buttons for network management. The Minimote can manage a Z-Wave network as primary controller. However it is also possible to reconfigure all 8 buttons for other functions e.g. activating a scene in a different controller.
Reset to factory default | Press the buttons "Association" and "Learn" together for 10 seconds to reset the device. |
Inclusion | Once the primary controller is turned into inclusion mode press the "Learn" button. |
Exclusion | Once the primary controller is turned into inclusion mode press the "Learn" button. |
NIF | A single click at the |
Wakeup | The device can be woken up manually by pressing the "Learn" button for 5 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation |
To delete a device from a scene repeat the process for the scene where the device was already associated with. |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Scene 1 |
2 | 5 | Scene 2 |
3 | 5 | Scene 3 |
4 | 5 | Scene 4 |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
Click the "Inclusion" button to start the inclusion mode.
If inclusion of a new device fails, first exclude it from its previous network or reset it.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
Click the "Exclusion" button to start the exclusion mode.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from its previous network.
The device can hand over its primary role to another controller and become secondary controller.
The primary shift is initiated on the device by pressing the "Learn" button.
Defines the switching mode of Button 1 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 2 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 3 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 4 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 5 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 6 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 7 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
01 | Scene Mode |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Defines the switching mode of Button 8 Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Factory Default |
02 | Add Mode |
03 | Remove Mode |
04 | Association Mode |
05 | Learn Mode |
Dimensions | 0.0340000x0.1000000x0.0110000 mm |
Weight | 29 gr |
EAN | 1220000010253 |
Specific Device Class | Remote Control |
Firmware Version | 01.00 |
Z-Wave Version | 02.4a |
Certification ID | ZC08-10080006 |
Z-Wave Product Id | 0086.0000.0000 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |