Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

Inclusion and Exclusion are confirmed by a single click on the button. If the Aeon Labs Inline Smart Energy Switch is not included into any Z-Wave network, the LED will be blinking continually.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Aeon Labs Inline Smart Energy Switch is a Z-Wave light switch specifically used to enable Z- Wave commands and control (on/off) a device that is connected to a standard Schuko Wall Outlet.

It can also report immediate wattage consumption or kWh energy usage over a period of time. The wireless module is powered from the mains supplys. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.

Installation

The Aeon Labs Inline Smart Energy Switch can be plugged between every Standard-Schuko wall outlet and the electrical appliance with maximum load of 3500W. To switch the plugged device on or off simply push the local button once or use a Z-Wave Controller. The status is shown by the status LED at the device.

Product Usage

The switch is operated by the local switch/button or wireless via Z-Wave. The click on the switch sets the switch on or off.

The Aeon Labs Inline Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z-Wave gateway or controller when requested. If this function is supported by the gateway/controller, the energy consumption will be displayed in the user interface of the gateway/controller. Please consult the operation manual for these gateways/controllers for specific instructions.

Reset to factory default XXXResetDescription
Inclusion To include the Aeon Labs Inline Smart Energy Switch with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If the Aeon Labs Micro Inline Smart Energy Switch was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed.
Exclusion To include the Aeon Labs Inline Smart Energy Switch with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If the Aeon Labs Micro Inline Smart Energy Switch was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed.
NIF

A single click at the Inclusion/Exclusion switch sends a Node Information Frame.

Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Status Reports

Configuration Parameters

Parameter 1: Type of Sensor Report

Defines the value type to be sent as Sensor Report.
Size: 1 Byte, Default Value: 00

Setting Description
00 Power
01 Voltage

Parameter 2: Blinking Behavior

This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
Size: 2 Byte, Default Value: 0000

Setting Description

Parameter 80: Notification on Status Change

Defines the automated status notification of an associated device when status changes
Size: 1 Byte, Default Value: 00

Setting Description
00 Deactivated
01 Hail sent
02 BASIC Report Sent

Parameter 90: Disables Function of automated sending of a Report triggered by minimal change of value.


Size: 1 Byte, Default Value: 00

Setting Description
00 Disabled
01 Enabled

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent .
Size: 2 Byte, Default Value: 0032

Setting Description
00 - 3500 Value in Watt

Parameter 92: Minimum Change to send Report (%)

The value represents the minimum change in Wattage Percent for a report to be sent
Size: 1 Byte, Default Value: 0a

Setting Description
00 - 100 Percentage

Parameter 101: Report type send in Reporting Group 1

Defines the type of report sent for the Reporting Group 1.
Size: 4 Byte, Default Value: 00000008

Setting Description
Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 102: Report Type send in Reporting Group 2

Defines the type of report sent for the Reporting Group 2.
Size: 4 Byte, Default Value: 00000000

Setting Description
Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 103: Report Type send in Reporting Group 3

Defines the type of report sent for the Reporting Group 3.
Size: 4 Byte, Default Value: 00000000

Setting Description
Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 111: Send Interval for Reporting Group 1

Defines the time interval when the defined report of Reporting Group 1 is sent out.
Size: 4 Byte, Default Value: 000002d0

Setting Description
00 - ffff Seconds

Parameter 112: Send Interval for Reporting Group 2

Defines the time interval when the defined report of Reporting Group 2 is sent out.
Size: 4 Byte, Default Value: 000002d0

Setting Description
00 - ffff Seconds

Parameter 113: Send Interval for Reporting Group 3

Defines the time interval when the defined report of Reporting Group 3 is sent out.
Size: 4 Byte, Default Value: 0000ffff

Setting Description
00 - ffff Seconds

Technical Data

Dimensions 0.0000000x0.0000000x0.0000000 mm
EAN 1220000011250
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.03
Z-Wave Version 02.61
Certification ID ZC08-13030009
Z-Wave Product Id 0086.0003.0006
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch