Quickstart

This is a Panic Button for XXXQFrequencyName. To run this device please insert fresh 1 * CR2450 3.0V batteries. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the inclusion process.
(Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.)



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Panic Watch is similar to the Panic Button, except for that this watch can be worn as a wristband. The Panic Watch is used within the Safety Services. With the Panic Watch you are able to send a message automatically to a preconfigured e-mail address. Actions from the Panic Watch can be programmed freely. The Panic Watch will operate on a single built-in battery. The expected lifetime is four years and a low battery signal will be send automatically.

Installation

Product Usage

Basic operations

- The Panic Watch can trigger any rule or lifestyle
- The Panic Watch can be configured to your needs
- The Panic Watch is easy to install and configured
- Indoor use only
- Water resistant
- Big red button with time configurable activation time

How it operates

After a successful inclusion the Panic Watch can be used. When pressing a button the led will blink to notice the customer that a successful alarm message is sent. With a controller you can make all different kind of rules and lifestyle changes. It also possible sent the alarm directly to a Z-Wave based alarm device.
V0.28 and higher has TOGGLE functionalities first time press the SOS-button it sends out alarm 0xFF next time SOS-button is pressed the panicwatch will sent reset alarm 0x00 message.

Use
1. Before use, the Panic Watch should be included into a Z-Wave network and associated.
2. You can test your Panic Watch by pressing the button for one second untill the led is turned on (press time is configurable).
3. Don’t forget to update and syncronize your rules in the Internet Gateway.

Indication mode
The indicator light gives various statuses of the device as follows:
1. Ready for learn mode: indicator light blinks every second
2. Learn in progress (add): indicator light 2 times every second
3. Learn in progress (remove): indicator light 3 times every 1.5 second
4. Learn mode success: indicator light is on for one second
5. RF message send success: indicator light is on for one second
6. RF message send failed: indicator light blinks 6 times rapidly
7. No association is set: indicator light blinks 6 times rapidly

Mode 1: Alarm mode
This mode is mainly used to notify a controller of an alarm or trigger an alarm on a Z-Wave supported alarm device.
Product can act on two types of handles. When single pressed (and hold): press and hold the button, the duration to hold depends on the configured values (parameter 2).
When double pressed: quickly (within 500 msec.) double press the button.

Mode 2: Control mode
This mode is mainly used to control a Z-Wave other device by directly sending a BASIC_ON or BASIC_OFF.
Product can act on two types of handles.
When single pressed (and hold): press and hold the button, the duration to hold depends on the configured
values (parameter 2).
When double pressed: quickly (within 500 msec.) double press the button.

Reset to factory default Set Parameter 1 to value 255
Inclusion Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the inclusion process.
(Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.)
Exclusion Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the exclusion process.
(Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.)
NIF XXXNIF
Wakeup Press and hold the Panic Watch for 14 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8
If configuration parameter 4 configured with value 0 then this group is used - SOS button: send ALARM_REPORT.
If configuration parameter 4 configured with value other then 0 (1-255) then this group is used - SOS button: send BASIC_SET, 0xFF.
2 8 Not used on application.

Configuration Parameters

Parameter 1: Set to default

Set all configuration values to default values (factory settings).
Size: 1 Byte, Default Value: 0

Setting Description
0 disable
255 set to default

Parameter 2: Time to press the Panic Watch

The time that the panic pushbutton must be pressed before a (panic) message is sent out to the controller.
Size: 1 Byte, Default Value: 1000

Setting Description
0 Send directly the panic message when pressed
1 - 255 Send a panic message after you keep holding the button pressed for this value x 10ms.

Parameter 3: Min. led feedback time panic

Minimum time that led feedback is shown after a panic message.
Size: 1 Byte, Default Value: 100

Setting Description
0 Led only stays on during the ‘send time’.
1 - 233 Led stays on during send time + this value*10ms.

Parameter 4: Buttons mapped

With this config parameter you can map the buttons to send different Z-Wave messages.
Size: 1 Byte, Default Value: 255

Setting Description
0 SOS button sends an ALARM_REPORT to nodes group 1
1 - 255 SOS button sends an BASIC_SET, 0xFF to nodes group 1

Technical Data

Dimensions 46 x 46 x 15 mm
Weight 33.6 gr
EAN 0632181493748
IP Class IP 21
Voltage 3V
Battery Type 1 * CR2450 3.0V
Device Type Panic Button
Generic Device Class Binary Sensor
Firmware Version 00.20
Z-Wave Version 03.2a
Z-Wave Product Id 0x008a.0x0015.0x0101
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropePanic Button