This is a
Press and hold the network button for 5 seconds.The thermostat must be in OFF mode.
The Z-Wave Plus enabled CT110 is a sleek, modern thermostat design for home automation systems.Its clean user interface compliments app-enabled systems, and it connects to a Z-Wave network with one touch.The CT110 features adjustable real-time alerts to enable cloud triggers, a robust data stream of HVAC information for cloud monitoring, and configurable comfort response settings to customize home control scenes.The CT110 is compatible with all popular HVAC systems and is battery-operated without the need for a C-wire.
Reset to factory default | Press the network button 5 times to factory reset the thermostat (will clear the network information).The thermostat must be in OFF mode.Use the reset procedure only when the primary controller is missing or inoperable. |
Inclusion | Press and hold the network button for 5 seconds.The thermostat must be in OFF mode. |
Exclusion | Press and hold the network button for 5 seconds.The thermostat must be in OFF mode. |
NIF | XXXNIF |
Wakeup | When included into a Z-Wave network on battery power, this device is a FLiRS device.The Thermostat will wake up for communication when it receives a valid Z-Wave beam. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 2 | Z-Wave Plus Lifeline |
The Temperature Reporting Threshold Con!guration Set Command sets the reporting threshold for Reporting Threshold changes in the ambient temperature as detected by the thermostat. Size: 1 Byte, Default Value: 2
Setting | Description |
---|
The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 31868 | Byte 1: 0 -124F (lower bound), Byte 2: 0-124F (upper bound) |
Enables or disables Simple UI mode on thermostat via RadioBus Read/Set UI command. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 = Normal Mode, 1 = Simple Mode |
This parameter controls how the thermostat sends unsolicited reports. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 = Disabled, 1 = Enabled |
This Conifuration Param on the CT110 sets what information is displayed in the main thermostat display area (the largest central numbers on the display) . Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 2 | 1=temperature 2=humidity |
This configuration value is used to read/white what behavior Save Energy Mode causes in the thermostat when the thermostat enters Save Energy Mode. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 255 | 1=Adjust by target delta, 2=Least consuming point in the running program, 3=Save energy absolute setpoint, 255=Save Energy not supported (read-only value) |
The HVAC Settings Configuration Report Command returns the current HVAC con!guration. The HVAC settings must be !xed before the thermostat is joined to the Z-Wave network. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2147483647 | Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages. |
The Utility Lock Con!guration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modi!ed directly via the thermostat screen. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | 0 = Disabled, 1 - 255 = Enabled |
The C-Wire / Battery Status Con!guration Report Command returns the status of the thermostat power source. The power state is fixed when the thermostat joins the network. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 2 | 1=C-Wire, 2=Battery |
The Humidity Threshold Con!guration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 3 | 0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH |
The Auxiliary/Emergency con!guration command enables or disables auxiliary / emergency heating in the thermostat. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 = Disabled, 1 = Enabled |
The Thermostat Swing Temperature configuration command sets swing temperature on the Temperature thermostat. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 8 | 1 = 0.5F, 2 = 1.0F, 3 = 1.5F, 4 = 2.0F, 5 = 2.5F, 6 = 3.0F, 7 = 3.5F, 8 = 4.0F |
The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. Size: 2 Byte, Default Value: 4
Setting | Description |
---|---|
2 - 6 | The thermostat di#erential temperature is in units of 0.5 degrees Fahrenheit. |
0 - 1 | 0x00 (Heat) or Cool (0x01) |
The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. The recovery mode determines when additional HVAC stages are turned of as the ambient temperature returns to the target temperature. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 2 | 1 = Fast, 2 = Economy |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15060005 |
Z-Wave Product Id | 0x0098.0x6E01.0x0000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |