Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Set primary controller to Include mode2. Press the Install Button



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The DB100Z is a battery powered, voltage sensing device that sends out a Notification report when voltage is detected at the sensor inputs.

Reset to factory default Please only perform a factory reset when the primary controller is missing or inoperable.A factory reset will remove all network settings and configurations. 1. Hold down Install Button for 10 seconds2. Release the Install Button3. When the Status LED begins to blink, the unit has finished restoring configuration
Inclusion 1.Set primary controller to Include mode2. Press the Install Button
Exclusion 1.Set primary controller to Exclude mode2. Press the Install Button
NIF XXXNIF
Wakeup When the Install Button is triple-pressed, the device will send a Wakeup Notification report and stay awake for 10 seconds.WAKEUP_INTERVAL_CAPABILITIES_REPORT Min Wake Up Interval :60 seconds Max Wake Up Interval: 86400 seconds Default Wake Up Interval: 25200 seconds Wake Up Interval Step: 60
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineBattery Report, Notification Report, Device Reset Locally Notification

Configuration Parameters

Parameter 1: Send Battery Report with Notification Report

This setting determines whether the battery level report will be sent when the notification report is sent by the device.
Size: 1 Byte, Default Value: 1

Setting Description
0 Do not send with the Notification Report
1 Send with the Notification Report

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15060028
Z-Wave Product Id 0x0178.0x4442.0x3130
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor