This is a
1. Have Z-Wave Controller entered inclusion mode.2. Pressing button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
The DCH-Z310 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn,based on Z-Wave technologyIt is the Z-Waveplus product, it supports the security, OTA... Those newestfeaturesoftheZ-Wave technology.Z-Wave isawireless communication protocol designed for home automation, specifically to remotelycontrolapplicationsinresidentialandlightcommercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing button four times within 1.5 seconds and do not release the button in the 4 thpressed, and the red LED will light ON.2. After the red LED flash 9 times, release the button within 2 seconds.3. IDs are removed and all settings will reset to factory default. |
Inclusion | 1. Have Z-Wave Controller entered inclusion mode.2. Pressing button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. |
Exclusion | 1. Have Z-WaveController entered exclusion mode.2. Pressing button three times within 1.5 seconds toenter the exclusion mode. Node ID has been removed. |
NIF | XXXNIF |
Wakeup | After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification messagetothenetwork,andwake-up20secondsforreceivethe setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12.The value is in minutes. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report thebattery level. |
Customer function switch, using bit control.Bit4: Notification Type,0: Using Notification Report. 1: Using Sensor Binary Report. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | Notification Type, Using Notification Report. |
16 | Notification Type, Using Sensor Binary Report. |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15030003 |
Z-Wave Product Id | 0x0108.0x0002.0x001E |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |