Quickstart

This is a Setpoint Thermostat for XXXQFrequencyName. To run this device please insert fresh 2 * AA 1,5V batteries. To run this device please make sure the internal battery is fully charged. Click on the function button "*" will confirm inclusion or exclusion and wakeup the device for wireless communication. A long push for 3 seconds on the function button enters and leaves the management mode indicated by a "M" on the LCD display.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This device is a Z-Wave controlled electronic radiator thermostat. It is mounted on wall heating valves and controls them by a motor. The device accepts a setpoint that is either set manually using buttons on the device or wirelessly using Z-Wave. Afterwards, the device will regulate the warm water supply to the wall radiator and compare the detected temperature to ensure, that the temperature in the room is kept at the desired level. A small LCD panel on the device displays the setpoint temperature on request.   Beside setting a desired temperature the device will support special heating schemes, such as energy saving and frost protection and intelligent functions like a valve training function to ensure that valves are still operational after longer periods. The Popp radiator thermostat can be mounted to valves with standard M30x1.5 connector or RA2000. Opposite to the Danfoss TRV this device will report the room temperature as detected and calculated by the device’s temperature sensor.

Installation

Adjustment to the radiator

The device can be adjusted to the room size. Three room sizes are known. The default size is P1. To change the assumed room size press (p) for 3 seconds to enter management mode (M in display). Press (v) until a "P" is displayed in the LCD display. Hit the (o) button. Now select 1, 2 or 3 using the arrow keys and exit with (o).

Removal

To remove the thermostat, insert an appropriate tool in the hole in the thermostat"s battery chamber (see illustration). Keeping the tool in position, turn the entire thermostat anticlockwise until it is completely unscrewed.

Adjusting to the valve

During the first night of operation lTRV will shut off the radiator heat and then open again to detect the exact opening point of the valve. This will allow TRV to control the heat as efficiently as possible. If necessary, the procedure is repeated once a night for up to a week. You might experience the valve being warm during the adjustment procedure, regardless of the room temperature.

Intelligent Control (Forecast)

During the first week of operation TRV learns when it is necessary to start heating the room in order to reach the correct temperature at the correct time. The intelligent control will continuously adjust the heating time compared to seasonal temperature changes.

Product Usage

The TRV is operated by wireless commands from a Z-Wave controller. 

  • Direct setting of Temperature Set Point by Controller. (Attention: There may be a delay in execution of a setpoint command due to the wakeup interval of the device. If the setpoint is to be changed at e.g. 16.00 and the wakeup interval is 15 minutes, make sure to send the command latest at 15.45)

The actual temperature setpoint is shown in the LCD display and can be overwritten by using the arrow keys on the device. This overwriting is temporary and only valid until the next change of the temperature setpoint (either triggered from external wireless command or from the internal downloaded schedule) becomes active.

The actual measured ambient temperature is not shown on the LCD display but is reported to the central gateway. 

The device will also recognize an open window (sudden temperature drop within short period of time) and turn down the heat for 30 minutes to save energy.

Local LCD Display

The local LCD display gives information about the status of the device

Link Test

The Thermostat allows to check the link quality to the controller device. Press the middle button (o) for 3 seconds until M is displayed. Select "LI" in display using the arrow keys, then confirm the link test with the middle button. A blinking antenna symbol indicates the link test. If the antenna symbol keeps flashing after about 3 seconds there is a problem with the wireless connection. If the antenna symbol stops flashing, the link quality is sufficient. A successfull link test will also terminate the exception mode described below.

The device applies multiple technologies to extend battery life. It is combining multi commands to a single command and adapt its behavior to the capabilities of the network controller. Make sure to use Danfoss Living connects only with Z-Wave controllers fully implementing all battery life time extention methods recommended by Danfoss. All controllers based on Z-Wave.Me software (e.g. RaZberry) fully support these methods.

When the battery level is low, the alarm bell icon flashes and the display will flash 8 times an hour between 19 and 22 hrs. If the battery goes flat, the system switches automatically to frost protection mode.

Reset to factory default Remove the batteries and keep the function button "*" pressed for 5 seconds after the batteries are inserted back.
Inclusion Click on the middle button will confirm inclusion or exclusion and wakeup the device for wireless communication. A long push for 3 seconds on the middle buttons enters and leaves the management mode indicated by a "M".
Exclusion Click on the middle button will confirm inclusion or exclusion and wakeup the device for wireless communication. A long push for 3 seconds on the middle buttons enters and leaves the management mode indicated by a "M".
NIF Clicking the function button
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Technical Data

Dimensions 51.000x51.000x91.000 mm
Weight 115 gr
Hardware Platform ZM3102
EAN 4250059693562
IP Class IP 20
Battery Type 2 * AA 1,5V
Device Type Central Controller
Generic Device Class Thermostat
Specific Device Class Setpoint Thermostat
Z-Wave Version 4.55.00
Certification ID ZC08-15020003
Z-Wave Product Id 0x0002.0x0005.0x0175
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeCentral Controller