This is a
MT02756 has temperature and humidity,based on Z-Wave technology. It is the Z-Wave plus product, it support the security, OTA... Those newest features of the Z-Waveâ technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default |
|
Inclusion | Pressing the tamper key three times within 1.5 seconds to manual inclusion with Z-Wave controller. |
Exclusion | Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. |
NIF | XXXNIF |
Wakeup | When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy. |
Protection | XXXProtection |
FirmwareUpdate | The device support the Z-Wave firmware update via OTA. Let the controller into the firmware update mode, and then press the tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the battery , otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30 seconds, and then re-install the battery. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
2 | 8 | The group 2 is for the light control, the device will send the Basic Set command to this group. |
Setting the BASIC command value.When the flood trigger off(0x00), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Setting the BASIC command value 0x00. |
Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Setting the BASIC command value 0xFF. |
Operation mode. Using bit to control.Bit0: Disable the Flood function.Bit1: Reserve.Bit2: Reserve.Bit3: Setting the temperature scale. 0: Fahrenheit, 1:CelsiusBit4: Reserve.Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)Bit6: Reserve.Bit7: Reserve. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Disable the Flood function. |
8 | Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
32 | Disable the temperature report after event triggered. (1:Disable, 0:Enable) |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
8 | Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. |
32 | Disable Multi CC in auto report. (1:Disable, 0:Enable) |
64 | Disable to report battery state when the device triggered. (1:Disable, 0:Enable) |
The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. |
The interval time for auto report the flood state. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the flood state. |
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 255 | The interval time for auto report each tick. |
Dimensions | 225x42x210 mm |
Weight | 40 gr |
Hardware Platform | SD3502 |
EAN | 4250059696709 |
IP Class | IP 20 |
Battery Type | 1 * CR123A |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17035462 |
Z-Wave Product Id | 0x0175.0x0002.0x0021 |
Supported Notification Types | Water Alarm |
Color | White |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |