Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged. The device have auto inclusion function, if the device not add into Z-Wave network, after power up, it will into the auto inclusion (NWI) mode. In this mode, let the Z-Wave Controller entered inclusion mode, the device will added. The NWI mode will timeout in 30 seconds. After that you can pressing the tamper key three times within 1.5 seconds to manual inclusion with Z-Wave controller. After inclusion successful, the device will awake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

MT02756 has temperature and humidity,based on Z-Wave technology. It is the Z-Wave plus product, it support the security, OTA... Those newest features of the Z-Waveâ technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Installation

Battery Installation

When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please press the top position, to release the cover.



Replace the new battery and install the cover back.
  1. Put the front cover bottom, and press down.
  2. Push the front cover top. Installation


Installation
  1. To mount the device on the wall, you can choose using the tape, or the screw.
  2. Using the screw to fix the flood detector.

 

Reset to factory default
  1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON. 
  2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 
  3. IDs are excluded and all settings will reset to factory default.
Inclusion Pressing the tamper key three times within 1.5 seconds to manual inclusion with Z-Wave controller.
Exclusion Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
NIF XXXNIF
Wakeup When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy.
Protection XXXProtection
FirmwareUpdate The device support the Z-Wave firmware update via OTA. Let the controller into the firmware update mode, and then press the tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the battery , otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30 seconds, and then re-install the battery.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline
2 8 The group 2 is for the light control, the device will send the Basic Set command to this group.

Configuration Parameters

Parameter 1: Basic Set OFF Level

Setting the BASIC command value.When the flood trigger off(0x00), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Setting the BASIC command value 0x00.

Parameter 2: Basic Set ON Level

Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Setting the BASIC command value 0xFF.

Parameter 5: Operation Mode

Operation mode. Using bit to control.Bit0: Disable the Flood function.Bit1: Reserve.Bit2: Reserve.Bit3: Setting the temperature scale. 0: Fahrenheit, 1:CelsiusBit4: Reserve.Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)Bit6: Reserve.Bit7: Reserve.
Size: 1 Byte, Default Value: 0

Setting Description
1 Disable the Flood function.
8 Setting the temperature scale. 0: Fahrenheit, 1:Celsius
32 Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Parameter 7: Customer Function


Size: 1 Byte, Default Value: 0

Setting Description
8 Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report. (1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 18

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 15: Auto Report Flood Time

The interval time for auto report the flood state. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 18

Setting Description
0 - 127 The interval time for auto report the flood state.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 The interval time for auto report each tick.

Technical Data

Dimensions 225x42x210 mm
Weight 40 gr
Hardware Platform SD3502
EAN 4250059696709
IP Class IP 20
Battery Type 1 * CR123A
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.06
Certification ID ZC10-17035462
Z-Wave Product Id 0x0175.0x0002.0x0021
Supported Notification Types Water Alarm
Color White
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor