Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. 1. In the Z-Wave-compatible control unit, start the procedure for adding a new device automatically.
2. Plug the Home Control Smart Metering Plug into an available power socket.
The Auto Inclusion is run. During the 2-minute timeout of the Auto Inclusion, Node Information Frames are sent within a few seconds.
In the auto inclusion, it is not necessary to press the ON/OFF button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The devolo Home Control Smart Metering Plug is an intelligent wall socket that adds useful additional functions to all wall sockets present in the household. This enables connected devices to be switched on and off based on time control, either using rules configured in the Z-Wave-compatible control unit or using the corresponding app. In addition, the devolo Home Control Smart Metering Plug has an energy consumption measurement feature.

Installation

Positioning the Home Control Smart Metering Plug optimally

1. Do not expose the Smart Metering Plug to direct sunlight and/or moisture. Avoid use in dusty environments.
2. The optimal ambient temperature for the device is between 0 and 35 degrees Celsius.
3. Do not place the Smart Metering Plug in environments with combustible materials or in the vicinity of heat sources such as fire, radiators, boilers etc.
It is normal for the housing to get a little warm when the device is plugged in.

Product Usage

LED Display

The LEDs indicate the device status:

Normal: In normal operation, the ON/OFF button switches between ON and OFF. The white LED is illuminated when the device is ready to operate; when the LED is switched off, the device is also switched
Inclusion with the control unit: If the Smart Metering Plug is in Inclusion mode, the white LED flashes at intervals of 0.5 sec.
Exclusion from the control unit: If the Smart Metering Plug is in Exclusion mode, the white LED flashes at intervals of 0.5 sec.
Inclusion with the control unit failed: If the process of including the Smart Metering Plug to the control unit has failed, the red LED flashes for one minute at time intervals of 0.5 seconds.
Classic inclusion with the control unit: During classic inclusion with the control unit (backwards compatibility), the red LED flashes at time intervals of 0.08 seconds.
Overload almost reached: If the Home Control Smart Metering Plug is exposed to a load of 11.7A for two seconds, the device signals the status Overload almost reached. The red LED is displayed constantly.
Overload: The Home Control Smart Metering Plug switches off automatically at an overload of 13A for 2 sec. The red LED flashes at time intervals of 0.15 sec. To restore function to the Home Control Smart Metering Plug, unplug it for around 10 seconds, then plug it in again.

Reset to factory default Press the ON/OFF button for at least 10 sec. to reset the device to the factory defaults. After the reboot, the device starts Auto Inclusion again.
Inclusion Press the button of the connected Smart Metering Plug 3x within 1.2 seconds to start the inclusion process with the Z-Wave-compatible control unit.
Exclusion Press the ON/OFF button 3x within 1.2 seconds to put the device into Exclusion mode. (indicated by white LED: 0.5 sec. ON, 0.5 sec. OFF)
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline

Configuration Parameters

Parameter 1: Watt Meter Report Period

If 1 hour is set (target value =720), the Home Control Smart Metering Plug reports its power consumption at the current time every hour to the Node ID of Group 1. The maximum reporting period is 45 hours(5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 Report Period in Unit 5s

Parameter 2: KWh Report Period

If 1 hour is set (target value =6), the Home Control Smart Metering Plug reports its accumulated power consumption every hour to the Node ID of Group 1. The maximum reporting period is227.55 days (10s*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 Report Period in Unit 10min

Parameter 3: Threshold of current for Load caution

If the current load exceeds the defined value, the Home Control Smart Metering Plug sends a meter message to the Node ID of Group 1.
Size: 2 Byte, Default Value: 1300

Setting Description
10 - 1300 Threshold in Unit 0.01A

Parameter 4: Threshold of KWh for Load caution

If the kW load exceeds the defined value (default value: 10,000, for an elevated accumulated power consumption), the Home Control Smart Metering Plug sends a meter message to the Node ID 1.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 Threshold in Unit 1 KWh

Parameter 5: Restore switch state mode

If the Home Control Smart Metering Plug is disconnected from the mains power supply and then reconnected to the mains power supply, depending on the configuration, it will trigger the Switch OFF, set the Last Switch State or set the Switch ON. The default setting is always the last switch state.
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off
1 Last switch state
2 Switch on

Parameter 6: Mode of Switch OFF function

If Switch ON/OFF is set to 0, both the Switch OFF command and the ON/OFF button are disabled. The default setting is the enable switching.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 7: LED indication mode

1 Display device statusWhen the Home Control Smart Metering Plug is switched on, the LED is on; when the Home Control Smart Metering Plug is switched off, the LED is off. In the default setting, the device status is displayed.2 Show nighttime mode:When the Home Control Smart Metering Plug is switched on, the LED is off; when the Home Control Smart Metering Plug is switched off, the LED is on.3 One-flash mode:If the device status changes, the LED flashes briefly (1 sec.) and then goes out.
Size: 1 Byte, Default Value: 1

Setting Description
1 Show switch state
2 Show night mode
3 One flash mode

Parameter 8: Auto off timer

If the Home Control Smart Metering Plug switches to ON, the auto-off timer starts counting down. After the timer is set to zero, the device shuts off automatically. If the auto-off timer function is set to 0, it is disabled.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable auto off function
1 - 32767 Auto-off time in Unit 1s

Parameter 9: RF off command mode

If the command Switch OFF BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF is received, this can be interpreted in four different ways:0. Switch OFF:The Home Control Smart Metering Plug switches itself off (default setting).1. Ignore:The command Switch OFF is ignored.2. Switch device:The Home Control Smart Metering Plug switches to the opposite state.3. Switch ON:The Home Control Smart Metering Plug switches itself on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch off
1 Ignore
2 Switch toggle
3 Switch on

Technical Data

Dimensions 60 x 60 x 80 mm
Weight 102 gr
Hardware Platform ZM5202
EAN 4250059699144
IP Class IP 20
Voltage 230 V
Load 3000 W
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.08
Certification ID ZC10-16125365
Z-Wave Product Id 0x0175.0x0001.0x0012
Firmware Updatable Updatable by Consumer by RF
Color White
Switch Type Push Button with Indicator
Supported Meter Type Electric Energy
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch