This is a
2. Plug the Home Control Smart Metering Plug into an available power socket.
The Auto Inclusion is run. During the 2-minute timeout of the Auto Inclusion, Node Information Frames are sent within a few seconds.
In the auto inclusion, it is not necessary to press the ON/OFF button.
The devolo Home Control Smart Metering Plug is an intelligent wall socket that adds useful additional functions to all wall sockets present in the household. This enables connected devices to be switched on and off based on time control, either using rules configured in the Z-Wave-compatible control unit or using the corresponding app. In addition, the devolo Home Control Smart Metering Plug has an energy consumption measurement feature.
LED Display
The LEDs indicate the device status:
Normal: In normal operation, the ON/OFF button switches between ON and OFF. The white LED is illuminated when the device is ready to operate; when the LED is switched off, the device is also switched
Inclusion with the control unit: If the Smart Metering Plug is in Inclusion mode, the white LED flashes at intervals of 0.5 sec.
Exclusion from the control unit: If the Smart Metering Plug is in Exclusion mode, the white LED flashes at intervals of 0.5 sec.
Inclusion with the control unit failed: If the process of including the Smart Metering Plug to the control unit has failed, the red LED flashes for one minute at time intervals of 0.5 seconds.
Classic inclusion with the control unit: During classic inclusion with the control unit (backwards compatibility), the red LED flashes at time intervals of 0.08 seconds.
Overload almost reached: If the Home Control Smart Metering Plug is exposed to a load of 11.7A for two seconds, the device signals the status Overload almost reached. The red LED is displayed constantly.
Overload: The Home Control Smart Metering Plug switches off automatically at an overload of 13A for 2 sec. The red LED flashes at time intervals of 0.15 sec. To restore function to the Home Control Smart Metering Plug, unplug it for around 10 seconds, then plug it in again.
Reset to factory default | Press the ON/OFF button for at least 10 sec. to reset the device to the factory defaults. After the reboot, the device starts Auto Inclusion again. |
Inclusion | Press the button of the connected Smart Metering Plug 3x within 1.2 seconds to start the inclusion process with the Z-Wave-compatible control unit. |
Exclusion | Press the ON/OFF button 3x within 1.2 seconds to put the device into Exclusion mode. (indicated by white LED: 0.5 sec. ON, 0.5 sec. OFF) |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
If 1 hour is set (target value =720), the Home Control Smart Metering Plug reports its power consumption at the current time every hour to the Node ID of Group 1. The maximum reporting period is 45 hours(5s*32767/3600=45hr). Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
1 - 32767 | Report Period in Unit 5s |
If 1 hour is set (target value =6), the Home Control Smart Metering Plug reports its accumulated power consumption every hour to the Node ID of Group 1. The maximum reporting period is227.55 days (10s*32767/1440=227.55 days). Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 32767 | Report Period in Unit 10min |
If the current load exceeds the defined value, the Home Control Smart Metering Plug sends a meter message to the Node ID of Group 1. Size: 2 Byte, Default Value: 1300
Setting | Description |
---|---|
10 - 1300 | Threshold in Unit 0.01A |
If the kW load exceeds the defined value (default value: 10,000, for an elevated accumulated power consumption), the Home Control Smart Metering Plug sends a meter message to the Node ID 1. Size: 2 Byte, Default Value: 10000
Setting | Description |
---|---|
1 - 10000 | Threshold in Unit 1 KWh |
If the Home Control Smart Metering Plug is disconnected from the mains power supply and then reconnected to the mains power supply, depending on the configuration, it will trigger the Switch OFF, set the Last Switch State or set the Switch ON. The default setting is always the last switch state. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Switch off |
1 | Last switch state |
2 | Switch on |
If Switch ON/OFF is set to 0, both the Switch OFF command and the ON/OFF button are disabled. The default setting is the enable switching. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
1 Display device statusWhen the Home Control Smart Metering Plug is switched on, the LED is on; when the Home Control Smart Metering Plug is switched off, the LED is off. In the default setting, the device status is displayed.2 Show nighttime mode:When the Home Control Smart Metering Plug is switched on, the LED is off; when the Home Control Smart Metering Plug is switched off, the LED is on.3 One-flash mode:If the device status changes, the LED flashes briefly (1 sec.) and then goes out. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Show switch state |
2 | Show night mode |
3 | One flash mode |
If the Home Control Smart Metering Plug switches to ON, the auto-off timer starts counting down. After the timer is set to zero, the device shuts off automatically. If the auto-off timer function is set to 0, it is disabled. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable auto off function |
1 - 32767 | Auto-off time in Unit 1s |
If the command Switch OFF BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF is received, this can be interpreted in four different ways:0. Switch OFF:The Home Control Smart Metering Plug switches itself off (default setting).1. Ignore:The command Switch OFF is ignored.2. Switch device:The Home Control Smart Metering Plug switches to the opposite state.3. Switch ON:The Home Control Smart Metering Plug switches itself on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch off |
1 | Ignore |
2 | Switch toggle |
3 | Switch on |
Dimensions | 60 x 60 x 80 mm |
Weight | 102 gr |
Hardware Platform | ZM5202 |
EAN | 4250059699144 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 3000 W |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-16125365 |
Z-Wave Product Id | 0x0175.0x0001.0x0012 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Switch Type | Push Button with Indicator |
Supported Meter Type | Electric Energy |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |