This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Spirit Z-Wave Plus is a Z-Wave radio standard compatible energy-saving radiator thermostat.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Buttons:
Boost-Taste Led‘s
LCD
Inserting batteries
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Inverts the LCD orientation Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal orientation |
1 | LCD content inverted |
Configures the timeout of the LCD. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LCD always on |
5 - 30 | LCD timeout in seconds |
Enables or disables the LCD-Backlight. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Backlight disabled |
1 | Backlight enabled |
Enables or disables unsolicited battery reporting once a day. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Battery reporting disabled |
1 | Battery reporting enabled |
Reports the measured roomtemperature on change. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 50 | Reporting Delta in 1/10 Celcius |
Reports the valve percentage on change. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 100 | Reporting Delta in percent |
Configures the sensitivity of the window open detection.Sensitivity level: 1 low2 medium3 high Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Detection disabled |
1 - 3 | Sensitivity level |
Configures an offset for the measured temperature. Set the offset to -128 (0x80) if measured temperature is provided externally. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | Offset in 1/10 Celcius (0°C - 5°C) |
128 | Temperature is supplied externaly |
206 - 255 | Offset in 1/10 Celcius (-5°C - 0,1°C) |
Dimensions | 56x68x89 mm |
Weight | 128 gr |
Hardware Platform | ZM5202 |
EAN | 4260012711301 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 2 * AA 1,5V |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17095777 |
Z-Wave Product Id | 0x0148.0x0003.0x0001 |
Supported Notification Types | Power ManagementSystem |
Thermostat HVAC Systems Supported | Heat Only |
Firmware Updatable | Updatable by Consumer by RF |
Thermostat Modes | Energy Save HeatHeat |
Sensors | Air Temperature |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |