Quickstart

This is a secure Thermostat - HVAC for XXXQFrequencyName. To run this device please insert fresh 2 * AA 1,5V batteries. To run this device please make sure the internal battery is fully charged.

- Start Inclusion mode of your primary Z-Wave Controller.
- Press the Boost-Button.
- Spirit Z-Wave Plus will show the assigned NodeID.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Spirit Z-Wave Plus is a Z-Wave radio standard compatible energy-saving radiator thermostat.

Installation

Mounting the Spirit Z-Wave Plus

After adding the Spirit Z-Wave Plus to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet.

Installation at the radiator without Adapter


Installation at the radiator with Adapter



Mechanical Installation

Press the boost button to start mechanical installation.



Unmounting the Spirit Z-Wave Plus





Product Usage

Buttons:



Boost-Taste Led‘s




LCD



Inserting batteries

Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct
polarity! At a later battery change, the configuration of your Spirit Z-Wave Plus is maintained.





Setpoint adjustment

The setpoint is adjusted via plus and minus button.
Altering the setpoint locally will set the Spirit Z-Wave Plus in heating mode.
The energy saving setpoint can only be adjusted via Z-Wave.
The configurable setpoint range is 8°C to 28°C.
If the setpoint is increased/decreased above/below the set point limits the
Spirit Z-Wave Plus will change into boost / off ?mode.
 

 Child protection
 
Press and hold plus and minus button simultaneously for 3 seconds
to enable/disable the child protection.
If the Spirit Z-Wave Plus is set into the highest protection level it is no
longer possible to operate the device locally.
 
Altering the operating states

Off-Mode
Press minus button until OFF is displayed.

Boost-Mode
Push the boost button.
Alternatively press the plus button until ON is displayed.

Heating-Mode
If the operating state is not heating mode, pressing the plus or
minus button will bring the device in heating mode.

Window open detection
If the roomtemperature drops the window open detection will trigger.
Spirit Z-Wave Plus will change temporarily in off mode for 15 minutes.
Window open detection will end automatically after 15 minutes and the previously active
operating mode will be restored.
Window open detection can also be canceled by a button press.
The window open detection is disabled during manufacturer specific mode.
The sensitivity oft he window open detection can be configured

Display NodeID
Press and hold the boost button for 3 seconds to display the NodeID.

Reset to factory default
Inclusion
Exclusion
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: LCD invert

Inverts the LCD orientation
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal orientation
1 LCD content inverted

Parameter 2: LCD Timeout

Configures the timeout of the LCD.
Size: 1 Byte, Default Value: 0

Setting Description
0 LCD always on
5 - 30 LCD timeout in seconds

Parameter 3: Backlight

Enables or disables the LCD-Backlight.
Size: 1 Byte, Default Value: 1

Setting Description
0 Backlight disabled
1 Backlight enabled

Parameter 4: Battery report

Enables or disables unsolicited battery reporting once a day.
Size: 1 Byte, Default Value: 1

Setting Description
0 Battery reporting disabled
1 Battery reporting enabled

Parameter 5: Measured temperature report

Reports the measured roomtemperature on change.
Size: 1 Byte, Default Value: 5

Setting Description
0 Reporting disabled
1 - 50 Reporting Delta in 1/10 Celcius

Parameter 6: Valve percentage report

Reports the valve percentage on change.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reporting disabled
1 - 100 Reporting Delta in percent

Parameter 7: Window open detection

Configures the sensitivity of the window open detection.Sensitivity level: 1 low2 medium3 high
Size: 1 Byte, Default Value: 2

Setting Description
0 Detection disabled
1 - 3 Sensitivity level

Parameter 8: Measured temperature offset

Configures an offset for the measured temperature. Set the offset to -128 (0x80) if measured temperature is provided externally.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 Offset in 1/10 Celcius (0°C - 5°C)
128 Temperature is supplied externaly
206 - 255 Offset in 1/10 Celcius (-5°C - 0,1°C)

Technical Data

Dimensions 56x68x89 mm
Weight 128 gr
Hardware Platform ZM5202
EAN 4260012711301
IP Class IP 20
Voltage 3V
Battery Type 2 * AA 1,5V
Device Type Thermostat - HVAC
Network Operation Listening Sleeping Slave
Z-Wave Version 6.71.01
Certification ID ZC10-17095777
Z-Wave Product Id 0x0148.0x0003.0x0001
Supported Notification Types Power ManagementSystem
Thermostat HVAC Systems Supported Heat Only
Firmware Updatable Updatable by Consumer by RF
Thermostat Modes Energy Save HeatHeat
Sensors Air Temperature
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeThermostat - HVAC