Quickstart

This is a On/Off Power Switch for Europe. To run this device please connect it to your mains power supply.

 

Inclusion and Exclusion are confirmed by a tripple click of the button of the device.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Everpring AN1576 is a switch plug that can be placed between a wall outlet for Plug-Type E (France, Poland, ...) and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The device is IP 20 rated and can therefore only be used in dry environments. Switching is controlled wirelessly using Z-Wave or locally applying a button. A red LED indicates the switching status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

The device can be plugged into every standard Schuko outlet. Do not locate the Module facing direct sunlight, humid or dusty place. The suitable ambient temperature for the module is 0°C ~ 40°C.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

tripple click of the button of the device.

Exclusion

tripple click of the button of the device.

Product Usage

Plug this module into a wall outlet near the load to be controlled. Plug the load into the module and switch the load to the ON position. To turn ON the module and the load plugged into it, press and release the ON/OFF button of the module.

The device is able to switch and measure any electric load up to 3000 W. Any load above 3000 W is considered as overloading. When overloading is detected the device will turn off the load, lock the local button and indicate the status by flashing the LED for 30 sec. Unplugging and replugging the module will reset the module to normal state. The electrical load can be switching using wireless commands and operating the local button. The LED inside the local button will indicate the switching status.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Technical Data

Dimensions 0.0060000x0.0090000x0.0070000 mm
Weight 140 gr
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.02
Z-Wave Version 02.40
Certification ID ZC08-09070011
Z-Wave Product Id 0060.0004.0001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes